English
Language : 

X93256_08 Datasheet, PDF (4/7 Pages) Intersil Corporation – Dual Digitally Controlled Potentiometers(XDCPs™)
X93256
DC Operating Characteristics Over recommended operating conditions, unless otherwise stated.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 7) (Note 4) (Note 7)
ICC1
VCC Active Current (Increment)
ICC2
VCC Active Current (Store)
(EEPROM Store)
ISB
Standby Supply Current
ILI
ILI
ILI
ILI
VIH
VIL
CIN
(Note 6)
CS input Leakage Current
CS input Leakage Current
CS input Leakage Current
INC, U/D Input Leakage Current
CS, INC, U/D input HIGH Voltage
CS, INC, U/D input LOW Voltage
CS, INC, U/D Input Capacitance
CS = VIL, U/D = VIL or VIH and
INC = 0.4V @ max. tCYC VCC = 3V
50
250
CS = VIL, U/D = VIL or VIH and
INC = 0.4V @ max. tCYC VCC = 5V
200
300
CS = VIH, U/D = VIL or VIH and
600
INC = VIH @ max. tWR VCC = 3V
CS = VIH, U/D = VIL or VIH and
INC = VIH @ max. tWR VCC = 5V
1400
CS = VCC - 0.3V, U/D and INC = VSS or
1
VCC - 0.3V VCC = 3V
CS = VCC - 0.3V, U/D and INC = VSS or
4
VCC - 0.3V VCC = 5V
VIN = VCC
±1
VCC = 3V, CS = 0
60
100
150
VCC = 5V, CS = 0
120
200
250
VIN = VSS to VCC
±1
VCC x 0.7
VCC + 0.5
-0.5
VCC x 0.1
VCC = 3V, VIN = VSS, TA = +25°C,
10
f = 1MHz (Note 5)
UNIT
µA
µA
µA
µA
µA
µA
µA
µA
µA
V
V
pF
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN
200,000
100
UNIT
Data changes per bit
Years
Test Circuit #1
TEST POINT
VH/RH
AC Conditions of Test
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
Circuit #2 SPICE Macro Model
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
AC Operating Characteristics Over recommended operating conditions, unless otherwise specified. In the table, CS, INC, U/D, RH and
RL are used to refer to either CS1 or CS2, etc.
SYMBOL
PARAMETER
MIN
(Note 7)
TYP
(Note 4)
MAX
(Note 7)
UNIT
tCl
CS to INC Setup
100
ns
tlD
INC HIGH to U/D Change
100
ns
tDI
U/D to INC Setup
100
ns
tlL
INC LOW Period
1
µs
tlH
INC HIGH Period
1
µs
4
FN8188.2
February 1, 2008