English
Language : 

X93155_08 Datasheet, PDF (4/8 Pages) Intersil Corporation – Digitally Controlled Potentiometer(XDCP™)
X93155
DC Electrical Specifications Over recommended operating conditions unless otherwise specified. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
(Note 7) (Note 4) (Note 7)
ILI
ILI
VIH
VIL
CIN
(Note 5)
CS
INC, U/D Input Leakage Current
CS, INC, U/D Input HIGH Voltage
CS, INC, U/D Input LOW Voltage
CS, INC, U/D Input Capacitance
VCC = 5V, CS = 0
120
200
250
VIN = VSS to VCC
±1
VCC x 0.7
VCC + 0.5
-0.5
VCC x 0.1
VCC = 5V, VIN = VSS, TA = +25°C,
10
f = 1MHz
UNIT
µA
µA
V
V
pF
Endurance and Data Retention
PARAMETER
MIN
UNIT
Minimum endurance
200,000 Data changes per bit
Data retention
100
Years
Test Circuit #1
TEST POINT
VH/RH
Circuit #2 SPICE Macro Model
RTOTAL
RH
RL
CH
CW
CL
10pF
10pF
25pF
AC Conditions of Test
VL
Input pulse levels
0V to 5V
Input rise and fall times
10ns
Input reference levels
1.5V
AC Electrical Specifications Over recommended operating conditions, unless otherwise specified.
SYMBOL
PARAMETER
MIN
(Note 7)
TYP
(Note 4)
tCl
CS to INC Setup
100
tlD
INC HIGH to U/D Change
100
tDI
U/D to INC Setup
100
tlL
INC LOW Period
1
tlH
INC HIGH Period
1
tlC
INC Inactive to CS Inactive
1
tCPH
CS Deselect Time (No Store)
250
tCPH
CS Deselect Time (Store)
10
tCYC
INC Cycle Time
2
tR, tF
INC Input Rise and Fall time
(Note 5)
tR VCC VCC Power-up Rate
1
(Note 5)
tWR
Store Cycle
5
MAX
(Note 7)
500
50
10
UNIT
ns
ns
ns
µs
µs
µs
ns
ms
µs
µs
V/ms
ms
4
FN8181.2
February 19, 2008