English
Language : 

X9015_15 Datasheet, PDF (4/12 Pages) Intersil Corporation – Single Digitally Controlled
X9015
Absolute Maximum Ratings
Temperature under bias . . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D, VH, VL and
VCC with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
V = |VH–VL| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V
Lead temperature (soldering 10s) . . . . . . . . . . . . . . . . . . . . . +300°C
IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±7.5mA
Operating Conditions
Temperature Range
Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (VCC)
X9015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%
X9015-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
)Potentiometer Specifications Over recommended operating conditions unless otherwise stated
SYMBOL
PARAMETER
TEST CONDITIONS/NOTES
RTOTAL
VVH
VVL
RW
RW
IW
End to End Resistance Variation
VH/RH Terminal Voltage
VL/RL Terminal Voltage
Power Rating
Wiper Resistance
Wiper Resistance
Wiper Current
Noise
RTOTAL 1k
IW = 1mA, VCC = 5V
IW = 1mA, VCC = 2.7V
Ref: 1kHz
Resolution
Absolute Linearity (Note 1)
Relative Linearity (Note 2)
RTOTAL Temperature Coefficient
Ratiometric Temperature Coefficient
Vw(n)(actual)–Vw(n)(expected)
Vw(n+1)–[Vw(n)+MI]
CH/CL/CW Potentiometer Capacitances
See circuit #3
MIN.
–20
0
0
-3.75
-1
-0.2
TYP.
200
400
-120
3
±300
10/10/25
MAX.
UNIT
+20
%
VCC
V
VCC
V
10
mW
400

1000

3.75
mA
dBV
%
+1 MI (Note 3)
+0.2 MI (Note 3)
ppm/°C
±20
ppm/°C
pF
Power Up and Down Requirements
The are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potentiometer pins
provided that VCC is always more positive than or equal to VH, VL, and VW, i.e., VCC VH, VL, VW. The VCC ramp rate spec is
always in effect.
NOTES:
1. Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage = (Vw(n)(actual)–Vw(n)(expected)) = ±1 Ml Maximum.
2. Relative Linearity is a measure of the error in step size between
taps = VW(n+1) – [Vw(n) + Ml] = ±0.2 Ml.
3. 1 Ml = Minimum Increment = RTOT/31.
4. Typical values are for TA = +25°C and nominal supply voltage.
5. This parameter is periodically sampled and not 100% tested.
4