English
Language : 

X90100 Datasheet, PDF (4/7 Pages) Xicor Inc. – NV Electronically Programmable Capacitor
X90100
Endurance and Data Retention VCC = 5V, TA = 25°C unless otherwise specified
PARAMETER
MIN
Minimum endurance
100,000
Data retention
100
UNIT
Data changes per bit
Years
AC Conditions of Test
Input pulse levels
Input rise and fall times
Input reference levels
0V to 3V
10ns
1.5V
AC Electrical Specifications VCC = 5V, TA = 25°C unless otherwise specified.
SYMBOL
PARAMETER
MIN
tCl
CS to INC setup
100
tlD
INC HIGH to U/D change
100
tDI
U/D to INC setup
100
tlL(7)
INC LOW period
1
tlH(7)
INC HIGH period
1
tlC
INC Inactive to CS inactive
1
tCPHNS(5) CS Deselect time (NO STORE)
1
tCPHS(5) CS Deselect time (STORE)
10
tIW
INC to CTOTAL change
tCYC
INC cycle time
4
tR, tF(5) INC input rise and fall time
tPU(5) Power up to capacitance stable
tR VCC(5) VCC power-up rate
0.2
tWR(5) Store cycle
AC Timing
TYP (4)
1
5
MAX
5
500
5
50
10
UNIT
ns
ns
ns
µs
µs
µs
µs
ms
µs
µs
µs
µs
V/ms
ms
CS
tCI
INC
tCYC
tIL
tIH
tIC
tID
tDI
(Store)
tCPHS
90% 90%
10%
tF
tR
tCPHNS
U/D
tIW
CTOTAL
(6)
MI
Notes: (6) MI in the A.C. timing diagram refers to the minimum incremental change in the CTOTAL output due to a change in the counter value.
(7) tIH + tIL ≥ 4µs
4
FN8156.0
February 2, 2005