Electrical Specifications Recommended operating conditions unless otherwise noted. Refer to Block Diagram and Typical Application
schematic. VCC = +5.0V ±10%, TA = -40 to 85°C (Note 9), Typical values are at TA = 25°C (Continued)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Start to Stop Hysteresis
0.2
0.5
0.8
V
SOFT-START - DIGITAL
COMP Rise Time
Rise from 0.5V to REF -1V
-
2048 clk
-
OSCILLATOR
Gate Output Frequency
Ct = 560pF
90
100
108
kHz
Gate Output Frequency Range
50
-
600
kHz
Temperature Stability
-
5
-
%
Sync. Frequency Range
1.1 Times the natural switching
-
frequency.
-
1.2
MHz
Sync Input HIGH
3.5
-
-
V
Sync Input LOW
-
-
1.5
V
Minimum Sync. Input Pulse Duty Cycle
-
20
-
%
OUTPUT
GATE Low Level
-
0.2
0.5
V
GATE High VSAT
Rise Time
C load = 1500pF
4.4
4.9
5.5
V
-
35
-
ns
Fall Time
C load = 1500pF
-
40
-
ns
NOTES:
9. Specifications at -40°C are guaranteed by design, not production tested.
10. This is the VCC current consumed when the device is active but not switching. Does not include gate drive current.
Typical Performance Curves
120
100
80
60
40
20
0
-40
-20
25
60
85
TEMPERATURE (°C)
FIGURE 1. FREQUENCY vs TEMPERATURE
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
-40
-20
25
60
85
TEMPERATURE (°C)
FIGURE 2. REFERENCE VOLTAGE vs TEMPERATURE
4
FN9007.7
April 13, 2005