Absolute Maximum Ratings
Voltage on VCC, CLK pins (respect to Gnd) . . . . . . . . -0.3V to 4.0V
Voltage on X1, X2 pins (respect to Gnd) . . . . . . . . . . . -0.3V to 2.5V
ESD Rating
MIL STD-883, Method 3014 . . . . . . . . . . . . . . . . . . . . . . . . .>±5kV
Machine Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>500V
Thermal Information
Thermal Resistance (Typical, Note 1)
θJA (°C/W) θJC (°C/W)
16 Ld QFN Package. . . . . . . . . . . . . . .
58
11
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . -65ºC to +150ºC
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
1. θJA is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See
Tech Brief TB379.
DC Electrical Specifications VCC = 3.3V ±10%, TA = -40ºC to +85ºC, Typical values are at TA = +25ºC and VCC = 3.3V,
Unless otherwise noted
SYMBOL
SYMBOL
CONDITIONS
MIN
TYP
MAX
Supply Voltage
VCC
Supply Voltage
3.0
3.3
3.6
Supply Current
ICC
Supply Current CL = 5pF on all outputs
11
15
CLOCK INPUT X2 (X1 GROUNDED) FOR EXTERNAL CLOCK MODE
Input High Level
VIH
1.5
2.4
Input Level Low
VIL
0.5
Input Current
IIL, IIH VX2 to Ground
0.5
CLOCK OUTPUTS (CLK)
Output High Level
Output Low Level
Output Short Circuit Current
VOH
VOL
IOSC
IOH = -100µA
IOH = -4mA
IOH = -6mA
IOL = 100µA
IOL = 4mA
IOL = 6mA
CLK = VCC or Gnd
VCC - 0.2
2.4
2.1
6
13
0.2
0.4
0.75
30
UNIT
V
mA
V
V
mA
V
V
V
V
V
V
mA
AC Electrical Specifications
SYMBOL
Crystal Frequency
CLOCK OUTPUTS
Rise Time
Fall Time
Duty Cycle
Period Jitter
Power Up Time
CL = 5pF on all outputs
SYMBOL
fIN
CONDITIONS
tR
20% to 80% VCC
tF
80% to 20% VCC
JP
RMS
tPO
VCC >2.7V
MIN
TYP
MAX
UNIT
30
MHz
1.8
ns
1.8
ns
40
60
%
50
ps
2
ms
3
FN6407.1
April 16, 2007