Electrical Specifications TA = 25°C Unless Otherwise Specified (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP
Output Leakage Currents of PBAR and
SBAR
Switchover Uncertainty for Complete
Switching of Inputs and Open Drain
Outputs
ILPBAR
ILSBAR
VP - VS
VP = 0V, VS = 15V, ILOAD = 0mA
at TA = +85°C
VP = 15V, VS = 0V, ILOAD = 0mA
at TA = +85°C
VS = 3V, ISINK = 3.2mA, ILOAD = 15mA
-
50
-
900
-
50
-
900
-
±10
NOTE:
3. The Minimum input to output voltage can be determined by multiplying the load current by the switch resistance.
MAX
500
-
500
-
±50
UNITS
nA
nA
nA
nA
mV
Typical Performance Curves
100
ILOAD = 15mA
100
ILOAD = 1mA
10
10
1
02
4 6 8 10 12 14 16
INPUT VOLTAGE VP (V)
FIGURE 1. ON-RESISTANCE SWITCH P1 AS A FUNCTION OF
INPUT VOLTAGE VP
1
0.8
0.6
0.4
0.2
-40°C
25°C
85°C
02
4 6 8 10 12 14 16
SUPPLY VOLTAGE (V)
FIGURE 3. SUPPLY CURRENT AS A FUNCTION OF SUPPLY
VOLTAGE
1
0
2
4
6
8
10
INPUT VOLTAGE VS
FIGURE 2. ON-RESISTANCE SWITCH P2 AS A FUNCTION OF
INPUT VOLTAGE VS
5
VO = 5V
VO = 9V
4
VO = 3V
VO = 12V
3
2
VO = 15V
1
0
40
80
120
140
180
OUTPUT CURRENT (mA)
FIGURE 4. PBAR OR SBAR SATURATION VOLTAGE AS A
FUNCTION OF OUTPUT CURRENT
3
FN3183.4
July 22, 2005