English
Language : 

RHRU10060 Datasheet, PDF (2/3 Pages) Intersil Corporation – 100A, 600V Hyperfast Diode
RHRU10060
Electrical Specifications TC = 25oC, Unless Otherwise Specified
SYMBOL
TEST CONDITION
MIN
TYP
MAX
UNITS
VF
IF = 100A
-
-
2.1
V
IF = 100A, TC = 150oC
-
-
1.7
V
IR
VR = 600V
-
VR = 600V, TC = 150oC
-
-
250
µA
-
2.0
mA
trr
IF = 1A, dIF/dt = 100A/µs
-
-
50
ns
IF = 100A, dIF/dt = 100A/µs
-
-
60
ns
ta
IF = 100A, dIF/dt = 100A/µs
-
28
-
ns
tb
IF = 100A, dIF/dt = 100A/µs
-
RθJC
-
18
-
ns
-
0.71
oC/W
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
trr = Reverse recovery time (See Figure 6), summation of ta + tb.
ta = Time to reach peak reverse current (See Figure 6).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 6).
RθJC = Thermal resistance junction to case.
pw = pulse width.
D = duty cycle.
Typical Performance Curves
500
175oC
100
100oC
10
25oC
1
0
0.5
1
1.5
2
2.5
3
VF, FORWARD VOLTAGE (V)
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE
5000
1000
175oC
100
100oC
10
25oC
1
0
100
200
300
400
500
600
VR, REVERSE VOLTAGE (V)
FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
2