RHRP6120CC
Absolute Maximum Ratings (Per Leg) TC = +25oC, Unless Otherwise Specified
RHRP6120CC
UNITS
Peak Repetitive Reverse Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRRM
1200
V
Working Peak Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRWM
1200
V
DC Blocking Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VR
1200
V
Average Rectified Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IF(AV)
6
A
TC = 130oC
Repetitive Peak Surge Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFSM
12
A
Square Wave, 20kHz
Nonrepetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFSM
60
A
Halfwave, 1 Phase, 60Hz
Maximum Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PD
50
W
Avalanche Energy (See Figures 10 and 11). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EAVL
10
mJ
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TSTG,TJ
-65 to +175
oC
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical Specifications (Per Leg) TC = +25oC, Unless Otherwise Specified
SYMBOL
TEST CONDITION
MIN
TYP
MAX
UNITS
VF
IF = 6A, TC = +25oC
IF = 6A, TC = +150oC
IR
VR = 1200V, TC = +25oC
VR = 1200V, TC = +150oC
-
-
3.2
V
-
-
2.6
V
-
-
100
µA
-
-
500
µA
tRR
IF = 1A, dIF/dt = 200A/µs
-
-
55
ns
IF = 6A, dIF/dt = 200A/µs
-
-
65
ns
tA
IF = 6A, dIF/dt = 200A/µs
-
33
-
ns
tB
IF = 6A, dIF/dt = 200A/µs
-
22
-
ns
QRR
IF = 6A, dIF/dt = 200A/µs
-
210
-
nC
CJ
RθJC
VR = 10V, IF = 0A
-
22
-
pF
-
-
3
oC/W
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
tRR = Reverse recovery time (See Figure 9), summation of tA + tB.
tA = Time to reach peak reverse current (See Figure 9).
tB = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
RθJC = Thermal resistance junction to case.
EAVL = Controlled Avalanche Energy (See Figures 10 and 11).
pw = pulse width.
D = duty cycle.