Absolute Maximum Ratings (Per Leg) TC = +25oC, Unless Otherwise Speciï¬ed
RHRP6120CC
UNITS
Peak Repetitive Reverse Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRRM
1200
V
Working Peak Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRWM
1200
V
DC Blocking Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VR
1200
V
Average Rectified Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IF(AV)
6
A
TC = 130oC
Repetitive Peak Surge Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFSM
12
A
Square Wave, 20kHz
Nonrepetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFSM
60
A
Halfwave, 1 Phase, 60Hz
Maximum Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PD
50
W
Avalanche Energy (See Figures 10 and 11). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EAVL
10
mJ
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TSTG,TJ
-65 to +175
oC
CAUTION: Stresses above those listed in âAbsolute Maximum Ratingsâ may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this speciï¬cation is not implied.
Electrical Speciï¬cations (Per Leg) TC = +25oC, Unless Otherwise Speciï¬ed
SYMBOL
TEST CONDITION
MIN
TYP
MAX
UNITS
VF
IF = 6A, TC = +25oC
IF = 6A, TC = +150oC
IR
VR = 1200V, TC = +25oC
VR = 1200V, TC = +150oC
-
-
3.2
V
-
-
2.6
V
-
-
100
µA
-
-
500
µA
tRR
IF = 1A, dIF/dt = 200A/µs
-
-
55
ns
IF = 6A, dIF/dt = 200A/µs
-
-
65
ns
tA
IF = 6A, dIF/dt = 200A/µs
-
33
-
ns
tB
IF = 6A, dIF/dt = 200A/µs
-
22
-
ns
QRR
IF = 6A, dIF/dt = 200A/µs
-
210
-
nC
CJ
RθJC
VR = 10V, IF = 0A
-
22
-
pF
-
-
3
oC/W
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
tRR = Reverse recovery time (See Figure 9), summation of tA + tB.
tA = Time to reach peak reverse current (See Figure 9).
tB = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
RθJC = Thermal resistance junction to case.
EAVL = Controlled Avalanche Energy (See Figures 10 and 11).
pw = pulse width.
D = duty cycle.