English
Language : 

MUR1620CT Datasheet, PDF (2/5 Pages) Motorola, Inc – ULTRAFAST RECTIFIERS 8 AMPERES 200-400-600 VOLTS
MUR1620CT, RURP820CC
Electrical Specifications (Per Leg) TC = 25oC, Unless Otherwise Specified
SYMBOL
TEST CONDITION
MIN
TYP
MAX
UNITS
VF
IF = 8A
IF = 8A, TC = 150oC
-
-
0.975
V
-
-
0.895
V
IR
VR = 200V
VR = 200V, TC = 150oC
-
-
100
µA
-
-
500
µA
trr
IF = 1A, dIF/dt = 200A/µs
-
-
25
ns
IF = 8A, dIF/dt = 200A/µs
-
-
30
ns
ta
IF = 8A, dIF/dt = 200A/µs
-
13
-
ns
tb
IF = 8A, dIF/dt = 200A/µs
-
5
-
ns
QRR
IF = 8A, dIF/dt = 200A/µs
-
25
-
nC
CJ
RθJC
VR = 10V, IF = 0A
-
60
-
pF
-
-
3
oC/W
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
trr = Reverse recovery time (See Figure 9), summation of ta + tb.
ta = Time to reach peak reverse current (See Figure 9).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
RθJC = Thermal resistance junction to case.
pw = Pulse width.
D = Duty cycle.
Typical Performance Curves
40
10
175oC 100oC 25oC
1
0.5
0
0.2
0.4
0.6
0.8
1
VF, FORWARD VOLTAGE (V)
1.2
1.4
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE
100
175oC
10
1
100oC
0.1
0.01
0.001
0
25oC
50
100
150
200
VR, REVERSE VOLTAGE (V)
FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
3-318