English
Language : 

X9269_07 Datasheet, PDF (16/24 Pages) Intersil Corporation – Dual Digitally-Controlled Potentiometers
X9269
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
ICC1
ICC2
ISB
ILI
ILO
VIH
VIL
VOL
VOH
VOH
Parameter
VCC supply current
(active)
VCC supply current
(nonvolatile write)
VCC current (standby)
Input leakage current
Output leakage cur-
Input HIGH voltage
Input LOW voltage
Output LOW voltage
Output HIGH voltage
Output HIGH voltage
Min.
Limits
Typ. Max.
400
Units
µA
1
5
mA
VCC x 0.7
-1
VCC - 0.8
VCC - 0.4
5
μA
10
μA
10
μA
VCC + 1
V
VCC x 0.3 V
0.4
V
V
V
Test Conditions
fSCL = 400kHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active, Read and
Volatile Write States only)
fSCL = 400kHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active,
Nonvolatile Write State only)
VCC = +6V; VIN = VSS or VCC; SDA = VCC;
(for 2-Wire, Standby State only)
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
IOH = -1mA, VCC ≥ +3V
IOH = -0.4mA, VCC ≤ +3V
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Units
Data changes per bit per register
years
CAPACITANCE
Symbol
CIN/OUT(6)
CIN(6)
Test
Input / Output capacitance (SDA)
Input capacitance (SCL, WP, A3, A2, A1 and A0)
Max.
8
6
Units
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
POWER-UP TIMING
Symbol
tr VCC(6)
tPUR(7)
Parameter
VCC Power-up rate
Power-up to initiation of read operation
Min.
0.2
Max.
50
1
Units
V/ms
ms
POWER-UP AND DOWN REQUIREMENTS
The are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the poten-
tiometer pins provided that VCC is always more positive than or equal to VH, VL, and VW, i.e., VCC ≥ VH, VL, VW. The
VCC power-up timing spec is always in effect.
A.C. TEST CONDITIONS
Input Pulse Levels
Input rise and fall times
VCC x 0.1 to VCC x 0.9
10ns
Input and output timing level
VCC x 0.5
Notes: (6) This parameter is not 100% tested
(7) tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued.
These parameters are periodically sampled and not 100% tested.
16
FN8173.4
April 17, 2007