English
Language : 

X9279 Datasheet, PDF (15/22 Pages) Xicor Inc. – Single Digitally-Controlled (XDCP) Potentiometer
X9279
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
Min. Typ. Max. Units
Test Conditions
ICC1
VCC supply current
(active)
3
mA fSCL = 400kHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active, Read
and Volatile Write States only)
ICC2
ISB
ILI
ILO
VIH
VIL
VOL
VOH
VCC supply current
(nonvolatile write)
VCC current (standby)
Input leakage current
Output leakage current
Input HIGH voltage
Input LOW voltage
Output LOW voltage
Output HIGH voltage
VCC x 0.7
-1
5
mA fSCL = 400kHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active,
Nonvolatile Write State only)
5
µA VCC = +6V; VIN = VSS or VCC;
SDA = VCC; (for 2-Wire, Standby
State only)
10
µA VIN = VSS to VCC
10
µA VOUT = VSS to VCC
VCC + 1
V
VCC x 0.3 V
0.4
V IOL = 3mA
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Units
Data changes per bit per register
years
CAPACITANCE
Symbol
CIN/OUT(6)
CIN(6)
Test
Input / Output capacitance (SDA)
Input capacitance (SCL, WP, A2, A1 and A0)
Max.
8
6
Units
pF
pF
Test Conditions
VOUT = 0V
VIN = 0V
POWER-UP TIMING
Symbol
tr VCC(6)
tPUR(7)
tPUW(7)
Parameter
VCC Power-up rate
Power-up to initiation of read operation
Power-up to initiation of write operation
Min.
0.2
Max.
50
1
50
Units
V/ms
ms
ms
A.C. TEST CONDITIONS
Input Pulse Levels
Input rise and fall times
Input and output timing level
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
Notes: (6) This parameter is not 100% tested
(7) tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued.
These parameters are periodically sampled and not 100% tested.
15
FN8175.2
September 27, 2005