ISL6551_06 Datasheet, PDF (14/26 Pages) Intersil Corporation – ZVS Full Bridge PWM Controller
ISL6551
• Ramp Adjust (R_RA, ISENSE)
- The ramp adjust block adds an offset component
(200mV) and a slope adjust component to the ISENSE
signal before processing it at the PWM Logic block, as
shown in Figure 9. This ensures that the ramp voltage is
always higher than the OAGS (ground sensing opamp)
minimum voltage to achieve a “zero” state.
- It is critical that the input signal to ISENSE decays to
zero prior to or during the clock dead time. The level-
shifting and capacitive summing circuits in the RAMP
ADJUST block are reset during the dead time. Any input
signal transitions that occur after the rising edge of CLK
and prior to the rising edge of RESDLY can cause
severe errors in the signal reaching the PWM
comparator.
- Typical ramp values are hundreds of mV over the period
on a 3V full scale current. Too much ramp makes the
controller look like a voltage mode PWM, and too little
ramp leads to noise issues (jitter). The amount of ramp
(Vramp), as shown in Figure 9, is programmed with the
R_RA resistor and can be calculated with Equation 10.
Vramp = BGREF x dt /(R_RA x 500E-12) (V)
(EQ. 10)
where dt = Duty Cycle / Fsw - tLEB (s). Duty cycle is
discussed in detail in application note AN1002.
- The voltage representation of the current flowing
through the power train at ISENSE pin is normally
scaled such that the desired peak current is less than or
equal to Vclamp-200mV-Vramp, where the clamping
voltage is set at the CSS pin.
• SYNC Outputs (SYNC1, SYNC2)
- SYNC1 and SYNC2 are the gate control signals for the
output synchronous rectifiers. They are biased by VDD
and are capable of driving capacitive loads up to 20pF
at 1MHz clock frequency (500kHz switching frequency).
These outputs are turned off sooner than the turn-off at
UPPER1 and UPPER2 by the clock dead time, DT.
- Inverting both SYNC signals or both LOWER signals is
another possible way to control the drivers of the
synchronous rectifiers. When using these drive
schemes, the user should understand the issues that
might occur in his/her applications, especially the
impacts on current share operation and light load
operation. Refer to application note AN1002 for more
details.
- External high current drivers controlled by the
synchronous signals are required to drive the
synchronous rectifiers. A pulse transformer is required
to pass the drive signals to the secondary side if the IC
is used in a primary control system.
• Share Support (SHARE, CS_COMP)
- The unit with the highest reference is the master. Other
units, as slaves, adjust their references via a source
resistor to match the master reference sharing the load
current. The source resistor is typically 1kΩ connecting
the EANI pin and the OUTPUT REFERENCE (external
reference or BGREF), as shown in Figure 10. The share
bus represents a 30kΩ resistive load per unit, up to 10
units.
- The output (ADJ) of “Operational Transconductance
Amplifier (OTA)” can only pull high and it is floating while
in master mode. This ensures that no current is sourced
to the OUTPUT REFERENCE when the IC is working
by itself.
- The slave units attempt to drive their error amplifier
voltage to be within a pre-determined offset (30mV
typical) of the master error voltage (the share bus). The
current-share error is nominally (30mV/EAO)*100%
assuming no other source of error. With a 2.5V full load
error amp voltage, the current-share error at full load
would be -1.2% (slaves relative to master).
- The bandwidth of the current sharing loop should be
much lower than that of the voltage loop to eliminate
noise pick-up and interactions between the voltage
regulation loop and the current loop. A 0.1µF capacitor
is recommended between CS_COMP and VSS pins to
achieve a low current sharing loop bandwidth (100Hz to
500Hz).
EAO
+
-
30mV
- ADJ
+
OTA
CS_COMP
0.1µF
1K
EANI
(+)
SHARE
OUTPUT
REFERENCE
30K
FIGURE 10. SIMPLIFIED CURRENT SHARE CIRCUIT