English
Language : 

X9119_08 Datasheet, PDF (12/17 Pages) Intersil Corporation – Single Digitally-Controlled (XDCP™) Potentiometer
X9119
Equivalent A.C. Load Circuit
SDA OUTPUT
5V
1533Ω
100pF
SDA OUTPUT
3V
867Ω
100pF
SPICE MACROMODEL
RTOTAL
RH
RL
CL
CW
CL
10pF
10pF
25pF
AC Timing High-Voltage Write Cycle Timing
PARAMETER
Clock Frequency
Clock Cycle Time
Clock High Time
Clock Low Time
Start Setup Time
Start Hold Time
Stop Setup Time
SDA Data Input Setup Time
SDA Data Input Hold Time
SCL and SDA Rise Time
SCL and SDA Fall Time
SCL Low to SDA Data Output Valid Time
SDA Data Output Hold Time
Noise Suppression Time Constant at SCL and SDA Inputs
Bus Free Time (Prior to Any Transmission)
A0, A1, A2 Setup Time
A0, A1, A2 Hold Time
SYMBOL
fSCL
tCYC
tHIGH
tLOW
tSU:STA
tHD:STA
tSU:STO
tSU:DAT
tHD:DAT
tR
tF
tAA
tDH
TI
tBUF
tSU:WPA
tHD:WPA
RW
MIN
2500
600
1300
600
600
600
100
0
250
0
50
1300
0
0
MAX
400
300
300
UNITS
kHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
High-Voltage Write Cycle Timing
PARAMETER
High-Voltage Write CycleTime (Store Instructions)
SYMBOL
tWR
TYP
5
MAX
10
UNITS
ms
XDCP Timing
PARAMETER
Wiper Response Time After theThird (Last) Power Supply is Stable
WiperResponse Time After Instruction Issued (All Load
Instructions)
SYMBOL
MIN
MAX
UNITS
tWRPO
tWRL
5
10
µs
5
10
µs
12
FN8162.4
July 9, 2008