X9110 Datasheet, PDF (11/18 Pages) Xicor Inc. – Single Digitally-Controlled (XDCP) Potentiometer
X9110
D.C. Operating Specifications Over the recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
ICC1
ICC2
ISB
VCC supply current
(active)
VCC supply current
(nonvolatile write)
VCC current (standby)
ILI
ILO
VIH
VIL
VOL
VOH
VOH
Input leakage current
Output leakage current
Input HIGH voltage
Input LOW voltage
Output LOW voltage
Output HIGH voltage
Output HIGH voltage
fSCK = 2.5 MHz, SO = Open, VCC = 5.5V
Other Inputs = VSS
fSCK = 2.5MHz, SO = Open, VCC = 5.5V
Other Inputs = VSS
SCK = SI = VSS, Addr. = VSS,
CS = VCC = 5.5V
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
IOH = -1mA, VCC ≥ +3V
IOH = -0.4mA, VCC ≤ +3V
VCC x 0.7
-1
VCC - 0.8
VCC - 0.4
TYP
1
MAX
400
5
3
10
10
VCC + 1
VCC x 0.3
0.4
UNITS
µA
mA
µA
µA
µA
V
V
V
V
V
Endurance and Data Retention
PARAMETER
Minimum Endurance
Data Retention
MIN
100,000
100
UNITS
Data changes per bit per register
years
Capacitance
SYMBOL
CIN/OUT (Notes 4,6)
COUT (Note 6)
CIN (Note 6)
TEST
Input/Output capacitance (SI)
Output capacitance (SO)
Input capacitance (A0, CS, WP, HOLD, and SCK)
TEST CONDITIONS
VOUT = 0V
VOUT = 0V
VIN = 0V
MAX
8
8
6
UNITS
pF
pF
pF
Power-up Timing
SYMBOL
PARAMETER
MIN
MAX
UNITS
tr VCC (Note 6) VCC Power-up Rate
0.2
50
V/ms
tPUR (Note7) Power-up to Initiation of read operation
1
ms
tPUW (Note 7) Power-up to Initiation of write operation
50
ms
NOTES:
6. This parameter is not 100% tested
7. tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued. These
parameters are not 100% tested.
8. ESD Rating on RH, RL, RW pins is 1.5kV (HBM, 1.0µA leakage maximum), ESD rating on all other pins is 2.0kV.
A.C. Test Conditions
Input pulse levels
Input rise and fall times
Input and output timing level
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
11
FN8158.2
October 7, 2005