English
Language : 

X9438 Datasheet, PDF (10/18 Pages) Intersil Corporation – Dual Digitally Controlled Potentiometer (XDCP) with Operational Amplifier
X9438
AMPLIFIER ELECTRICAL CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Symbol
VOS
TCVOS
IB
IOS
CMRR
PSRR
VCM
AV
VO
IO
IS
GB
SR
ΦM
Parameter
Input offset voltage
Input offset voltage temp.
coefficient
Input bias current
Input offset current
Common mode
rejection ratio
Power supply
rejection ratio
Input common mode voltage
range
Large signal voltage gain
Output voltage swing
Output current
Supply current
Gain-bandwidth prod
Slew rate
Phase margin
Condition
V+/V- ±3V to ±5V
V+/V- ±3V to ±5V
V+/V- ±3V to ±5V
V+/V- ±3V to ±5V
VCM = -1V to +1V
V+/V- ±3V to ±5V
Industrial
Commercial
Min. Typ. Max. Min. Typ. Max.
1
3
1
2
-10
-10
Unit
mV
µV/°C
50
50
pA
25
25
pA
70
70
dB
70
70
dB
Tj = 25°C
V-
V+ V-
V+
V
VO = -1V to + 1V
V-
V+
30 50
+0.1
V+/V- = ±5.5V
50
V+/V- = ±3.3V
30
V+/V- = ±5.0V
V+/V- = ±3.0V
RL = 100k, CL = 50pf
1.0
RL = 100k, CL = 50pf
1.5
RL = 100k, CL = 50pf
80
30 50
+0.1
-.15
50
30
3
1.5
1.0
1.5
80
V/mV
V
-.15
V
mA
mA
3
mA
1.5 mA
MHz
V/µsec
Deg.
V+ and V- (±5V to ±3V) are the amplifier power supplies. The amplifiers are specified with dual power supplies. VCC and VSS
is the logic supply. All ratings are over the temperature range for the Industrial (-40 to + 85°C) and Commercial (0 to 70°C)
versions of the part unless specified differently.
SYSTEM/DIGITAL D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC
VCC supply current (active)
Min.
Limits
Typ. Max.
400
Unit
µA
ISB
VCC current (standby)
ILI
Input leakage current
ILO
Output leakage current
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL
Output LOW voltage
VCC x 0.7
-0.5
1
µA
10
µA
10
µA
VCC + 0.5
V
VCC x 0.1
V
0.4
V
Test Conditions
fSCL = 400kHz, SDA = Open,
Other Inputs = VSS
SCL = SDA = VCC, Addr. = VSS
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
10