HS-1840ARH-T Datasheet, PDF (1/3 Pages) Intersil Corporation – Radiation Hardened 16 Channel CMOS Analog Multiplexer with High-Z Analog Input Protection | |||
|
Data Sheet
HS-1840ARH-T
July 1999 File Number 4589.1
Radiation Hardened 16 Channel CMOS
Analog Multiplexer with High-Z Analog
Input Protection
Intersilâs Satellite Applications FlowTM (SAF) devices are fully
tested and guaranteed to 100kRAD Total Dose. These QML
Class T devices are processed to a standard ï¬ow intended
to meet the cost and shorter lead-time needs of large
volume satellite manufacturers, while maintaining a high
level of reliability.
The HS-1840ARH-T is a Radiation Hardened, monolithic 16
channel multiplexer constructed with the Intersil Rad-Hard
Silicon Gate, Dielectric Isolation process. It is designed to
provide a high input impedance to the analog source if
device power fails (open), or the analog signal voltage
inadvertently exceeds the supply by up to ±35V, regardless
of whether the device is powered on or off. Selection of one
of sixteen channels is controlled by a 4-bit binary address
plus an Enable-Inhibit input, which conveniently controls the
ON/OFF operation of several multiplexers in a system. All
inputs have electrostatic discharge protection.
Speciï¬cations
Speciï¬cations for Rad Hard QML devices are controlled by
the Defense Supply Center in Columbus (DSCC). The SMD
numbers listed below must be used when ordering.
Detailed Electrical Speciï¬cations for the HS-1840ARH-T
are contained in SMD 5962-95630. A âhot-linkâ is provided
from our website for downloading.
www.intersil.com/spacedefense/newsafclasst.asp
Intersilâs Quality Management Plan (QM Plan), listing all
Class T screening operations, is also available on our
website.
www.intersil.com/quality/manuals.asp
Ordering Information
ORDERING
NUMBER
PART
NUMBER
TEMP.
RANGE
(oC)
5962R9563002TXC
HS1-1840ARH-T
-55 to 125
HS1-1840ARH/Proto
HS1-1840ARH/Proto
-55 to 125
5962R9563002TYC
HS9-1840ARH-T
-55 to 125
HS9-1840ARH/Proto
HS9-1840ARH/Proto
-55 to 125
NOTE: Minimum order quantity for -T is 150 units through
distribution, or 450 units direct.
Features
⢠QML Class T, Per MIL-PRF-38535
⢠Radiation Performance
- Gamma Dose (γ) 1 x 105 RAD(Si)
- No Latch-Up, Dielectrically Isolated Device Islands
⢠Improved rDS(ON) Linearity
⢠Improved Access Time 1.5µs (Max) Over Temp and Rad
⢠High Analog Input Impedance 500M⦠During Power Loss
(Open)
⢠±35V Input Over Voltage Protection (Power On or Off)
⢠Excellent in Hi-Rel Redundant Systems
⢠Break-Before-Make Switching
Pinouts
HS1-1840ARH-T (SBDIP), CDIP2-T28
TOP VIEW
+VS 1
NC 2
NC 3
IN 16 4
IN 15 5
IN 14 6
IN 13 7
IN 12 8
IN 11 9
IN 10 10
IN 9 11
GND 12
(+5VS) VREF 13
ADDR A3 14
28 OUT
27 -VS
26 IN 8
25 IN 7
24 IN 6
23 IN 5
22 IN 4
21 IN 3
20 IN 2
19 IN 1
18 ENABLE
17 ADDR A0
16 ADDR A1
15 ADDR A2
HS9-1840ARH-T (FLATPACK) CDFP3-F28
TOP VIEW
+VS
NC
NC
IN 16
IN 15
IN 14
IN 13
IN 12
IN 11
IN 10
IN 9
GND
(+5VS) VREF
ADDR A3
1
28
2
27
3
26
4
25
5
24
6
23
7
22
8
21
9
20
10
19
11
18
12
17
13
16
14
15
OUT
-VS
IN 8
IN 7
IN 6
IN 5
IN 4
IN 3
IN 2
IN 1
ENABLE
ADDR A0
ADDR A1
ADDR A2
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
www.intersil.com or 407-727-9207 | Copyright © Intersil Corporation 1999
Satellite Applications Flow⢠(SAF) is a trademark of Intersil Corporation.
|
▷ |