English
Language : 

D2RV-L22E Datasheet, PDF (1/4 Pages) Omron Electronics LLC – High Reliability for Micro Load Applications, Even in Adverse Atmospheres (Dust, High Humidity, Silicon Gas, etc.)
D2RV
Miniature Basic Switch
High Reliability for Micro Load
Applications, Even in Adverse
Atmospheres (Dust, High
Humidity, Silicon Gas, etc.)
● The reed switch offers exceptional contact
D
2
reliability in micro load applications.
R
● Same mounting pitch as for the V Miniature Basic
V
Switch.
● High durability with a bounce time of 1 ms max.
RoHS Compliant
Model Number Legend
Contact Form
D2RV-@1 @2
1. Actuator
None : Pin plunger model
L11 : Short hinge lever
L : Hinge lever
L13 : Simulated roller lever
L22 : Short hinge roller lever
L2 : Hinge roller lever
2. Maximum Operating Force (OF)
None : 0.49 N {50 gf}
E : 0.25 N {25 gf}
(for pin plungers only)
G : 0.98 N {100 gf}
Note. These values are for the pin plunger models.
List of Models
Actuator
Pin
plunger
Short hinge
lever
Hinge lever
Simulated
roller lever
Short hinge
roller lever
Hinge roller
lever
Maximum
Operating
Force (OF)
0.25 N {25 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.25 N {25 gf}
0.49 N {50 gf}
0.25 N {25 gf}
0.49 N {50 gf}
0.49 N {50 gf}
0.98 N {100 gf}
0.25 N {25 gf}
0.49 N {50 gf}
Model
D2RV-E
D2RV
D2RV-G
D2RV-L11
D2RV-L11G
D2RV-L
D2RV-LG
D2RV-L13
D2RV-L13G
D2RV-L22
D2RV-L22G
D2RV-L2
D2RV-L2G
●SPST-NO
Reed switch
NO
COM
Ratings
Switching voltage
Switching current
Contact capacity
100 VDC (max.)
0.25 ADC (max.)
10 WDC (max.)
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Characteristics
Permissible operating speed
Permissible
operating
frequency
Mechanical
Electrical
Insulation resistance
Contact resistance (initial value)
Between terminals of
the same polarity
Dielectric
strength * 1
Between current-
carrying metal parts and
ground
Between each terminal
and non-current-
carrying metal parts
Vibration
resistance * 2
Malfunction
Shock
resistance
Destruction
Malfunction * 2
Mechanical
Durability * 3
Electrical
Degree of protection
Ambient operating temperature
Ambient operating humidity
Weight
0.1mm to 1 m/s (for pin plunger models)
200 operations/min
200 operations/min
100 MΩ min. (at 500 VDC with insulation tester)
150 mΩ max.
200 VDC 1 min
500 VAC 50/60 Hz for 1 min
500 VAC 50/60 Hz for 1 min
10 to 55 Hz, 1.5 mm double amplitude
500 m/s2 {approx. 50G} max.
200 m/s2 {approx. 20G} max.
10,000,000 operations min. (60 operations/min)
3,000,000 operations min. (30 operations/min)
IEC IP40
–10°C to +60°C (at ambient humidity of 60% max.)
(with no icing or condensation)
80% max. (for +5°C to +35°C)
Approx. 7g (for pin plunger models)
Note. The data given above are initial values.
*1. The values for dielectric strength shown are for models with a Separator
(refer to "Basic Switch Common Accessories").
*2. For the pin plunger models, the above values apply for use at the free
position and total travel position. For the lever models, they apply at the
total travel position. Close or open circuit of the contact is 1ms max.
*3. For testing conditions, consult your OMRON sales representative.
Separator (Sold Separately), Actuator (Sold Separately), Terminal Connector (Sold Separately) Refer to "Basic Switch Common Accessories"