English
Language : 

MS5541-30C Datasheet, PDF (5/19 Pages) Intersema Sensoric SA – MINIATURE 30 bar MODULE
PRESSURE OUTPUT CHARACTERISTICS
With the calibration data stored in the interface IC of the MS5541-30C the following characteristics can be
achieved:
(VDD = 3.0 V unless noted otherwise)
Parameter
Conditions
Min
Typ Max
Unit
Note
Resolution
3.0
mbar
1
Absolute Pressure Accuracy
(Temperature range 0 .. +40 °C)
Absolute Pressure Accuracy
(Temperature range -40 .. +85 °C)
Error over Temperature
(p = const. relative to 20°C)
p = 0 .. 10bar
p = 0 .. 20bar
p = 0 .. 30bar
p = 0 .. 10bar
p = 0 .. 20bar
p = 0 .. 30bar
Ta = -40…+85°C
-50
-100
-250
-100
-150
-400
-25
+50
mbar
+50
mbar
2
+50
mbar
+250 mbar
+450 mbar
3
+500 mbar
+250 mbar
Long-term Stability
6 months
50
mbar
4
Maximum Error over Supply
Voltage
VDD = 2.2…3.6V
-40
+40
mbar
NOTES
1) A stable pressure reading of the given resolution requires taking the average of 2 to 4 subsequent pressure
values due to noise of the ADC.
2) Maximum error of pressure reading over the pressure range.
3) With the second-order temperature compensation as described in Section “FUNCTION". See next section
for typical operating curves.
4) The long-term stability is measured with non-soldered devices
TEMPERATURE OUTPUT CHARACTERISTICS
This temperature information is not required for most applications, but it is necessary to allow for temperature
compensation of the pressure output. The reference temperature is 20°C.
Parameter
Resolution
Accuracy
Maximum Error over Supply
Voltage
Conditions
Ta = 20°C
Ta = -40…+85°C
VDD = 2.2…3.6V
Min Typ Max
0.005
0.015
-0.8
0.8
-2
+6
-0.2
0.2
Unit
°C
°C
°C
°C
Note
1
NOTE
1) With the second-order temperature compensation as described in Section “FUNCTION". See next section
for typical operating curves.
DA5541-30C_001.doc
Sept. 25th, 2008
5
0005541C1348 ECN1143