English
Language : 

MS5535C Datasheet, PDF (5/21 Pages) Intersema Sensoric SA – PRESSURE SENSOR MODULE
PRESSURE OUTPUT CHARACTERISTICS
With the calibration data stored in the interface IC of the MS5535C the following characteristics can be achieved:
Parameter
Resolution
Absolute Pressure Accuracy
(Temperature range 0 .. +40°C)
Absolute Pressure Accuracy
(Temperature range -40 .. +85°C)
Absolute Pressure Accuracy
(Temperature range -40 .. +125°C)
Long-term Stability
Maximum Error over Supply
Voltage
Conditions
p = 0 .. 5 bar
p = 0 .. 10 bar
p = 0 .. 14 bar
p = 0 .. 5 bar
p = 0 .. 10 bar
p = 0 .. 14 bar
p = 0 .. 5 bar
p = 0 .. 10 bar
p = 0 .. 14 bar
6 months
VDD = 2.2 .. 3.6 V
Min
-25
-60
-150
-40
-60
-160
-80
-100
-300
-16
(VDD = 3.0 V unless noted otherwise)
Typ Max
Unit Notes
1.2
mbar
1
+20
+20
mbar
2
+20
+100
+180 mbar
2
+200
+200
+200 mbar
2
+200
20
mbar
3
+16
mbar
NOTES
1) A stable pressure reading of the given resolution requires taking the average of 2 to 4 subsequent pressure
values due to noise of the ADC.
2) Maximum error of pressure reading over the pressure range.
3) The long-term stability is measured with non-soldered devices.
TEMPERATURE OUTPUT CHARACTERISTICS
This temperature information is not required for most applications, but it is necessary to allow for temperature
compensation of the pressure output.
(VDD = 3.0 V unless noted otherwise)
Parameter
Conditions
Min
Typ Max
Unit Notes
Resolution
0.005 0.01 0.015
°C
Accuracy
T = 20°C
-0.8
T = -40 .. +125°C
-4
Maximum Error over Supply
Voltage
VDD = 2.2 .. 3.6 V
-0.2
0.8
°C
+6
°C
1
0.2
°C
NOTE
1) With the second-order temperature compensation as described in Section “FUNCTION". See next section
for typical operating curves.
DA5535C_003.doc
June 16th, 2008
5
000055351195 ECN1118