English
Language : 

MHV283R3S_10 Datasheet, PDF (9/19 Pages) Interpoint Corporation Company – Operating temperature -55° to +125°C Input voltage range 16 to 50 VDC
Crane Aerospace & Electronics Power Solutions
MHV Single, Dual and Triple DC/DC Converters
28 Volt input – 15 Watt
Electrical Characteristics: -55° to +125°C TC, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL output models
PARAMETER
CONDITIONS
OUTPUT VOLTAGE
OUTPUT CURRENT
±Vout
Each Output
Vin = 16 to 50 VDC
OUTPUT POWER 2
Total
Each Output
Vin = 16 to 50 VDC
OUTPUT RIPPLE
LINE REGULATION
Balanced Loads
Total
±VOUT, 10 kHz - 2 MHz
Vin = 16 to 50 VDC
LOAD REGULATION
Balanced Loads
No Load to Full
INPUT VOLTAGE
CONTINUOUS
TRANSIENT 120 ms 1
INPUT CURRENT
NO LOAD
INHIBITED
INPUT RIPPLE CURRENT
10 kHz - 10 MHz
EFFICIENCY
LOAD FAULT 3
STEP LOAD RESPONSE 4
Balanced Loads
POWER DISSIPATION
SHORT CIRCUIT
RECOVERY 1
50% - 100% - 50%
TRANSIENT
RECOVERY
STEP LINE
RESPONSE 1, 5
±Vout
16 - 50 - 16 Vin
TRANSIENT
RECOVERY
START-UP
Vin = 40 V
CAPACITIVE LOAD 1
+VOUT DELAY
-VOUT DELAY
OVERSHOOT 1
25°C
MHV2805D
MIN TYP MAX
4.90 5.00 5.10
0
—
1.5
—
—
3
0
—
7.5
—
—
15
—
5
35
—
0
10
MHV2812D
MIN TYP MAX
11.76 12.00 12.24
0
—
0.625
—
—
1.25
0
—
7.5
—
—
15
—
5
25
—
0
10
MHV2815D
MIN TYP MAX
14.70 15.00 15.30
0
—
0.50
—
—
1.0
0
—
7.5
—
—
15
—
10
50
—
0
10
UNITS
VDC
A
W
mV p-p
mV
—
5
20
—
2
20
—
2
20
mV
16
28
50
16
28
50
16
28
50
VDC
—
—
80
—
—
75
—
—
60
V
—
22
30
—
32
43
—
37
50
—
8.4
10
—
8.4
10
—
8.4
10
mA
—
5
40
—
5
40
—
10
45 mA p-p
75
79
—
79
83
—
78
83
—
%
—
—
8.5
—
—
10
—
—
10
W
—
—
20
—
—
25
—
—
30
ms
—
— ±350 —
—
±400
—
— ±500 mV pk
—
—
3.0
—
—
1.5
—
—
1.5
ms
—
— ±400 —
—
±500
—
— ±500 mV pk
—
—
4.0
—
—
3.0
—
—
3.0
ms
—
10
18
—
10
20
—
12
22
ms
—
10
20
—
10
25
—
12
30
—
0
100
—
0
240
—
0
300 mV pk
—
—
100
—
—
100
—
—
100
µF
Notes
1. Guaranteed by design, not tested.
2. Up to 7.5 watts is available from either output.
3. Load fault is a short circuit (<50 mΩ). Recovery is into a resistive load.
4. Step load transition ≥ 10 µs. Recovery = time to settle to within 1% of VOUT final value.
5. Step line transition ≥ 10 µs. Recovery = time to settle to within 1% of VOUT final value.
www.interpoint.com
Page 9 of 19
MHV Rev E - 20100503