English
Language : 

FMTR283R3S Datasheet, PDF (8/8 Pages) Interpoint Corporation Company – EMI FILTERED DC/DC CONVERTERS 28 VOLT INPUT
FMTR SERIES
30 WATT
DC/DC CONVERTERS
ENVIRONMENTAL SCREENING
TEST
125°C
STANDARD
PRE-CAP INSPECTION 25°C
Method 2017, 2032
yes
TEMPERATURE CYCLE (10 times)
Method 1010, Cond. B, -55°C to 125°C
no
CONSTANT ACCELERATION 25°C
Method 2001, 500 g
no
BURN-IN
96 hours at 125°C case (typical)
no
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A
Subgroups 1 and 4: +25°C case
yes
HERMETICITY TESTING 25°C
Fine Leak, Method 1014, Cond. A
no
Gross Leak, Method 1014, Cond. C
no
Gross Leak, Dip (1 x 10-3)
yes
125°C
/ES
yes
yes
yes
yes
yes
yes
yes
no
FINAL VISUAL INSPECTION 25°C
Method 2009
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
Contact Information:
Interpoint Headquarters USA
Phone: 1-800-822-8782
+425-882-3100
Email: power@intp.com
www.interpoint.com
Interpoint UK
Phone: +44-1252-872266
Email: poweruk@intp.com
Interpoint France
Phone: +33-134285455
Email: powerfr@intp.com
FMTR 28001-001-DTS Rev E. This revision supercedes all previous releases.
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
8
products or specifications without notice. FMTR Series is a trademark of Interpoint.
Copyright © 1994 - 2002 Interpoint Corporation. All rights reserved.