English
Language : 

IL33153 Datasheet, PDF (3/3 Pages) Integral Corp. – SINGLE IGBT GATE DRIVER
IL33153
ELECTRICAL CHARACTERISTICS (Vcc=15V, VEE=0V, Kelvin Gnd connected to VEE. For typical values
TA=25°C, for min/max values TA is the operating ambient temperature range that applies (Note 2), unless otherwise noted.)
Characteristic
Symbol
Min
Typ
Max
Unit
LOGIC INPUT
Input Threshold Voltage ]
V
High State (Logic 1 )
Low State (Logic 0)
Input Current
VIH
-
2.70
3.2
VIL
1.2
2.30
-
µA
High State (VIH = 3.0 V)
Low State (Vii. = 1.2 V)
IIH
IIL
DRIVE OUTPUT
-
130
500
-
50
100
Output Voltage
V
Low State (Isink = 1.0 A)
High State (Isource = 500 mA)
Output Pull-Down Resistor
VOL
VOH
RPD
FAULT OUTPUT
-
2.0
2.5
12
13.9
-
-
100
200
kΩ
Output voltage
V
Low Slate (Isink = 5.0 mA)
High State (Isource = 20 mA)
VFL
-
VFH
12
SWITCHING CHARACTERISTICS
0.2
1.0
13.3
-
Propagation Delay (50% Input to 50% Output CL = 1.0 nF)
ns
Logic Input to Drive Output Rise
Logic Input to Drive Output Fall
tPLH(in/out) tPHL -
(in/out)
-
80
300
120
300
Drive Output Rise Time (10% to 90%) CL = 1.0 nF
tr
Drive Output Fall Time (90% to 10%) CL= 1.0 nF
tf
Propagation Delay
-
17
55
ns
-
17
55
ns
µs
Current Sense Input to Drive Output
Fault Blanking/Desaturation Input to Drive Output
tp(OC)
tp(FLT)
UVLO
-
0.3
1.0
-
0.3
1.0
Startup Voltage
Disable Voltage
VSS Start
VSS dis
COMPARATORS
11.3
12
10.4
11
12.6
V
11.7
V
Overcurrent Threshold Voltage (Vpin8 > 7,0 V)
VSOC
50
65
80
mV
Short Circuit Threshold Voltage (Vpine8> 7,0 V)
VSSC
100
130
160
mV
Fault Blanking/Desaturation Threshold (Vpin1 > 100 mV)
Vth(FLT)
6.0
6.5
7.0
V
Current Sense Input Current (Vsi = 0 V)
ISI
-
-1.4
-10
mA
FAULT BLANKING/DESATURATION INPUT
Current Source (Vpjn8 = 0 V, Vpin4 = 0 V)
Ichg
-200
-270
-300
mA
Discharge Current (Vpin8 = 15 V, Vpin4 = 5.0 V)
Idschg
1.0
2.5
-
mA
TOTAL DEVICE
Power Supply Current
ICC
mA
Standby (Vpin 4 = VCC, Output Open)
Operating (CL= 1.0 nF, f= 20 kHz)
-
7.2
14
-
7.9
20
NOTES: 1. Kelvin Ground must always be between VEE and VCC.
2.Low duty cycle pulse techniques are used during test to maintain the junction temperature as close
to ambient as possible.
Tlow = -40°C lor IL33153
Thigh = +105°Clor IL33153
3