ILA4605-2 Datasheet, PDF (1/3 Pages) Integral Corp. – Control IC for Switched Mode Power Supplies using MOS Transistors
ILA4605-2
Control IC for Switched Mode Power Supplies using MOS
Transistors
The IC ILA 4605-2 controls the MOS - power transistor and performs all necessary
regulation and monitoring function in free running flyback converters. Because of the fact
that a wide load range is achieved, this IC is applicable for consumer as well as industrial
power supplies.
The serial circuit and primary winding of the flyback transformer are connected in series to
the input voltage. During the switch - on period of the transistor, energy is stored in the
transformer. During the switch - off period the energy is fed to the load via the secondary
winding. By varying switch - on time of the Power transistor, the IC controls each portion of
energy transferred to the secondary side such that the output voltage remains nearly
independent of load variations. The required control information is taken from the input
voltage during the switch - on period and from a regulation winding during the switch - off
period. A new cycle will start if the transformer has transferred the stored energy
completely into the load.
FEATURES:
• Fold - back characteristics provides overload protection for external components
• Burst operation under secondary short - circuit condition implemented
• Protection against open or short of the control loop
• Switch - off if line voltage is too low (undervoltage switch - off)
• Line voltage depending compensation of fold - back point
• Soft start for quiet start - up without noise generated by the transformer
• Chip - over temperature protection (thermal shutdown)
P-DIP-8-1
• On - chip ringing suppression circuit against parasitic oscillations of the transformer
In the different voltage ranges the switched - mode Power supply (SMPS) behaves as
follow:
No load operation. The Power supply is operating in the burst mode at typical 20 to 40
kHz. The output voltage can be a little bit higher or lower than the nominal value
depending on the design of the transformer and the resistors of the control voltage divider.
Nominal operation. The switching frequency is reduced with increasing load and
decreasing AC voltage. The duty factor primarily depends on the AC voltage. The output
voltage is only depends on the load.
Overload point. Maximum output Power is available at this point of the output
characteristic.
Overload. The energy transferred per operation cycle is limited at the top. Therefore the
output voltages declines by secondary overloading.
PIN DEFINITION
Pin # Function
1.
Information Input Concerning Secondary Voltage
2.
Information Input Regarding the Primary Current
3.
Input for Primary Voltage Monitoring
4.
Ground
5.
Output
6.
Supply Voltage Input
7.
Input for Soft Start and Integrator Circuit
8.
Input for the Feedback of the Oscillator