English
Language : 

V23826-C18-C64 Datasheet, PDF (8/15 Pages) Infineon Technologies AG – DC/DC (5 V/3.3 V) Single Mode 155 MBd ATM/SDH/SONET 1x9 Long Haul Transceiver
V23826-C18-C64
V23826-C18-C364
Technical Data
Receiver Electro-Optical Characteristics
Parameter
Sensitivity (Average Power)1)
Saturation (Average Power)
Signal Detect Assert Level2)
Signal Detect Deassert Level3)
Signal Detect Hysteresis
Signal Detect Assert Time
Signal Detect Deassert Time
Output Low Voltage4)
Output High Voltage4)
Output Data, Rise/Fall Time,
20%–80%
Output SD Rise/Fall Time5)
Symbol
min.
PIN
PSAT
PSDA
PSDD
PSDA –
PSDD
tASS
tDAS
VOL – VCC
VOH – VCC
tR, tF
–2
-44
1
–1950
–1025
Limit Values
typ.
max.
–36
–34
-37.5
-40
2.5
-34
6
100
350
–1620
–720
375
40
Unit
dBm
dB
µs
mV
ps
ns
1) Minimum average optical power at which the BER is less than 1x10-10. Measured with a 223 - 1 NRZ PRBS as
recommended by ANSI T1E1.2, SONET OC-3, and ITU-T G.957.
2) An increase in optical power of data signal above the specified level will cause the SIGNAL DETECT to switch
from a Low state to a High state.
3) A decrease in optical power of data signal below the specified level will cause the SIGNAL DETECT to switch
from a High state to a Low state.
4) DC/DC for data, DC/DC PECL for Signal Detect, PECL compatible. Load is 50 Ω into VCC – 2 V for data, 500 Ω
to VEE for Signal Detect. Measured under DC conditions. For dynamic measurements a tolerance of 50 mV
should be added. VCC = 3.3 V / 5 V. TAMB = 25°C.
5) PECL compatible. A high level on this output shows that an optical signal is applied to the optical input.
Data Sheet
8
2000-03-01