TLE6228_10 Datasheet, PDF (8/19 Pages) Infineon Technologies AG – Smart Quad Channel Low-Side Switch
D a t a s h e e t T L E 6 2 2 8 G P
If current overload or overtemperature occurs for a longer time than tDSO, the fault condition is latched
into an internal register and the output is shutdown. The reset is done by switching off the corresponding
control input for a time longer than tD-IN.
Open load is detected for all four channels in on and off mode.
In the on mode the load current is monitored. If it drops below the specified threshold value IQU then an
open load condition is detected.
In the off mode, the output voltage is monitored. An open load condition is detected when the output
voltage of a given channel is below the threshold VDS(OL), which is typ. 33 % of the supply voltage VS. To
prevent an open load diagnosis in case of transient Voltages on the outputs the open load detection in
off mode uses a filter of typ. 50µs.
Status output at pulse width operation
If the input is operated with a pulsed signal, the status does not follow each single pulse of the input sig­
nal. An internal delay tD of typ. 1.2ms ( min 500 ms) enables a continuous status output signal. See the
timing diagrams on the following pages for further information.
This internal status delay simplifies diagnostic software for pwm applications.
Diagnostic Table
In general the status follows the input signal in normal operating conditions.
If any error is detected the status is inverted.
Operating Condition
Standby1)
Normal function
Open load or short to ground
Overload or short to supply2)
reset latch 3)
Overtemperature2)
reset latch 3)
Standby
Input
STBY
L
H
H
H
H
H
H
H
H
H
H
H
H
H
Enable
Input
ENA
X
L
H
H
L
L
H
H
H
H
L
H
H
L
Control
Input
IN
X
X
L
H
L
H
L
H
H
HfiL
X
H
HfiL
X
Power
Output
Q
off
off
off
ON
off
off
off
ON
off
off
off
off
off
off
Status
Output
ST
H
L
L
H
H
H
H
L
L
L
L
L
L
L
V4.1
Page 8
2010-07-10