English
Language : 

TLE5205-2_07 Datasheet, PDF (8/25 Pages) Infineon Technologies AG – 5-A H-Bridge for DC-Motor Applications
TLE 5205-2
Diagnosis
2
Diagnosis
Various errors as listed in the table “Diagnosis” are detected. Short circuits and overload
result in turning off the output stages after a delay tdSD and setting the error flag
simultaneously [EF = L]. Changing the inputs to a state where the fault is not detectable
resets the error flag (input toggling) with the exception of short circuit from OUT1 to
OUT2 (load short circuit).
Flag
Open circuit between OUT1 and OUT2
Short circuit from OUT1 to OUT2
Short circuit from OUT1 to GND
Short circuit from OUT2 to GND
Short circuit from OUT1 to VS
Short circuit from OUT2 to VS
Overtemperature or undervoltage
IN1 IN2 OUT1 OUT2 EF Remarks
Nr.
00H
L
1 Not detectable 1
01L
H
1 Not detectable 2
10L
L
1 Not detectable 3
11Z
Z
0
4
0 0 VS/2 VS/2 0
5
0 1 VS/2 VS/2 0
6
10L
L
1 Not detectable 7
11Z
Z
1 Not detectable 8
0 0 GND L
0 1 GND H
1 0 GND L
1 1 GND L
0
9
1 Not detectable 10
1 Not detectable 11
1 Not detectable 12
00H
01L
10L
11L
GND 1
GND 0
GND 1
GND 1
Not detectable 13
14
Not detectable 15
Not detectable 16
0 0 VS
L
0 1 VS
H
1 0 VS
H
1 1 VS
H
1 Not detectable 17
0
18
0
19
1 Not detectable 20
00H
01L
10H
11H
VS
0
21
VS
1 Not detectable 22
VS
0
23
VS
1 Not detectable 24
00Z
Z
0
25
01Z
Z
0
26
10Z
Z
0
27
11Z
Z
0
28
IN: 0 = Logic LOW OUT: Z = Output in tristate condition
EF:
1 = Logic HIGH
= VS /2 due to internal Pull-up/down resistors
L = Output in sink condition
H = Output in source condition
1 = No error
0 = Error
Data Sheet
8
Rev. 1.1, 2007-07-31