English
Language : 

BTS6480SF Datasheet, PDF (64/73 Pages) Infineon Technologies AG – SPI Power Controller
SPOC - BTS6480SF
Serial Peripheral Interface (SPI)
10.5
SPI Protocol 16Bit
CS1) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Write OUT Register
SI
1 0 0 0 0 0 0 0 0 0 OUT5 OUT4 OUT3 OUT2 OUT1 OUT0
Read OUT Register
SI
000000xxxxxxxxx0
Write Configuration and Control Registers
SI
1x
ADDR
DATA
Read Configuration and Control Registers
SI
0x
ADDR
xxxxxxxxx0
Read Standard Diagnosis
SI
0xxxxxxxxxxxxxx1
Standard Diagnosis
SO TER 0 LHI SBM x CLE x x x x x x x ERR3 ERR2 ERR1 ERR0
Second Frame of Read Command
SO TER 1 0 0 0 0 0 x x x x OUT5 OUT4 OUT3 OUT2 OUT1 OUT0
SO TER 1 x
ADDR
DATA
1) The SO pin shows this information between CS hi -> lo and first SCLK lo -> hi transition.
Note: Reading a register needs two SPI frames. In the first frame the RD command is sent. In the second frame
the output at SPI signal SO will contain the requested information. A new command can be executed in the
second frame. The standard diagnosis can be accessed either by sending the standard diagnosis read
command or it is transmitted after each write command.
Field
W/R
RB
TER
OUTn
n = 5 to 0
ADDR
DATA
ERRn
n = 3 to 0
Bits
15
14
CS
n
13:10
9:0
n
Type
w
rw
r
w
rw
rw
r
Description
0 Read
1 Write
Register Bank
0 Read / write to register bank 0
1 Read / write to register bank 1
Transmission Error
0 Previous transmission was successful (modulo 16 clocks received)
1 Previous transmission failed or first transmission after reset
Output Control Register of Channel n
0 OFF
1 ON
Address
Pointer to register for read and write command
Data
Data written to or read from register selected by address ADDR
Diagnosis of Channel n 1)
0 No failure
1 Over temperature, over load or short circuit
Data Sheet
64
Rev. 1.0, 2010-04-12