English
Language : 

SAFC167CRLMHA Datasheet, PDF (63/89 Pages) Infineon Technologies AG – 16-Bit Single-Chip Microcontroller
C167CR
C167SR
Electrical Parameters
Table 11 DC Characteristics (Operating Conditions apply)1) (cont’d)
Parameter
Symbol Limit Values Unit Test Condition
Min. Max.
Output high voltage3)
(PORT0, PORT1, Port 4, ALE,
RD, WR, BHE, CLKOUT,
RSTOUT)
VOH CC 2.4
–
0.9 VDD –
V IOH = -2.4 mA
V IOH = -0.5 mA
Output high voltage3)
(all other outputs)
Input leakage current (Port 5)
VOH1 CC
IOZ1 CC
2.4
0.9 VDD
–
–
–
±200
V IOH = -1.6 mA
V IOH = -0.5 mA
nA 0 V < VIN < VDD
Input leakage current
(all other)4)
IOZ2 CC –
RSTIN inactive current5)
RSTIN active current5)
READY/RD/WR inact. current8)
READY/RD/WR active current8)
ALE inactive current8)
ALE active current8)
Port 6 inactive current8)
Port 6 active current8)
PORT0 configuration current9)
IRSTH6)
IRSTL7)
IRWH6)
IRWL7)
IALEL6)
IALEH7)
IP6H6)
IP6L7)
IP0H6)
IP0L7)
–
-100
–
-500
–
500
–
-500
–
-100
±500
-10
–
-40
–
40
–
-40
–
-10
–
nA 0.45 V < VIN <
VDD
µA VIN = VIH1
µA VIN = VIL
µA VOUT = 2.4 V
µA VOUT = VOLmax
µA VOUT = VOLmax
µA VOUT = 2.4 V
µA VOUT = 2.4 V
µA VOUT = VOL1max
µA VIN = VIHmin
µA VIN = VILmax
XTAL1 input current
IIL CC –
±20
µA 0 V < VIN < VDD
Pin capacitance10)
(digital inputs/outputs)
CIO CC –
10
pF f = 1 MHz;
TA = 25 °C
1) Keeping signal levels within the levels specified in this table, ensures operation without overload conditions.
For signal levels outside these specifications also refer to the specification of the overload current IOV.
2) Valid in bidirectional reset mode only.
3) This specification is not valid for outputs which are switched to open drain mode. In this case the respective
output will float and the voltage results from the external circuitry.
4) This parameter is not valid for pins READY, ALE, RD, and WR while the respective pull device is on.
5) These parameters describe the RSTIN pull-up, which equals a resistance of ca. 50 to 250 kΩ.
6) The maximum current may be drawn while the respective signal line remains inactive.
7) The minimum current must be drawn in order to drive the respective signal line active.
8) This specification is valid during Reset and during Hold-mode or Adapt-mode. During Hold-mode Port 6 pins
are only affected, if they are used (configured) for CS output and the open drain function is not enabled. The
READY-pull-up is always active, except for Power-down mode.
Data Sheet
61
V3.3, 2005-02