3.3.6 Peripheral Timings
XMCâ¢1200 AB-Step
XMCâ¢1000 Family
Electrical Parameter
Note: These parameters are not subject to production test, but verified by design and/or
characterization.
3.3.6.1 Synchronous Serial Interface (USIC SSC) Timing
The following parameters are applicable for a USIC channel operated in SSC mode.
Note: Operating Conditions apply.
Table 29 USIC SSC Master Mode Timing
Parameter
Symbol
Values
Min. Typ. Max.
SCLKOUT master clock tCLK CC 62.5 â â
period
Slave select output SELO t1 CC 80
active to first SCLKOUT
transmit edge
ââ
Slave select output SELO t2 CC 0
inactive after last
SCLKOUT receive edge
ââ
Data output DOUT[3:0]
valid time
t3 CC -10
â 10
Receive data input
t4 SR 80
DX0/DX[5:3] setup time to
SCLKOUT receive edge
ââ
Data input DX0/DX[5:3] t5 SR 0
hold time from SCLKOUT
receive edge
ââ
Unit Note /
Test Condition
ns
ns
ns
ns
ns
ns
Data Sheet
61
V1.7, 2016-08