TLE4921-3U Datasheet, PDF (6/19 Pages) Infineon Technologies AG – Dynamic Differential Hall Effect Sensor IC | |||
|
◁ |
TLE 4921-3U
Operating Range
Parameter
Supply voltage
Junction temperature
Pre-induction
Differential induction
Symbol Limit Values
min.
max.
VS
4.5
24
Tj
â 40
170
B0
â 500 500
âB
â 80
80
Unit Remarks
Vâ
°C â
mT at Hall probe;
independent of
magnet orientation
mT â
Note: In the operating range the functions given in the circuit description are fulfilled.
AC/DC Characteristics
Parameter
Symbol Limit Values
min. typ. max.
Supply current
IS
4.7 6.1 8.0
5.1 6.7 8.8
Output saturation
voltage
Output leakage
current
Center of
switching points:
(âBOP + âBRP) / 2
Operate point
VQSat
IQL
âBm
âBOP
Release point
âBRP
Hysteresis
âBHy
Overvoltage
protection at supply VSZ
voltage at output VQZ
Output rise time
tr
â
0.25 0.6
â
â 10
â1 0 1
â
â0
0
ââ
0.5 1.5 2.5
27 â 35
27 â 35
â
â 0.5
Unit Test Condition Test
Circuit
mA VQ = high
1
IQ = 0 mA
mA VQ = low
1
IQ = 40 mA
V IQ = 40 mA
1
µA VQ = 24 V
1
mT â 20 mT < âB < 2
20 mT 1) 2)
f = 200 Hz
mT f = 200 Hz,
2
âB = 20 mT
mT f = 200 Hz,
2
âB = 20 mT
mT f = 200 Hz,
2
âB = 20 mT
V IS = 16 mA
1
V IS = 16 mA
1
µs IQ = 40 mA
1
CL = 10 pF
Data Sheet
6
2000-07-01
|
▷ |