English
Language : 

C167CS-L16M3V Datasheet, PDF (55/81 Pages) Infineon Technologies AG – 16-Bi t Single-Chip Microcontroller
C167CS-L16M3V
Low Power
DC Characteristics (cont’d)
(Operating Conditions apply)1)
Parameter
Symbol Limit Values Unit Test Condition
min. max.
RSTIN active current5)
IRSTL7) -100
–
READY/RD/WR inact. current8) IRWH6) –
-10
READY/RD/WR active current8) IRWL7) -500
–
ALE inactive current8)
IALEL6) –
20
ALE active current8)
IALEH7) 500
–
Port 6 inactive current8)
IP6H6)
–
-10
Port 6 active current8)
IP6L7)
-500
–
PORT0 configuration current9) IP0H6) –
-5
IP0L7)
-100
–
µA VIN = VIL
µA VOUT = 2.4 V
µA VOUT = VOLmax
µA VOUT = VOLmax
µA VOUT = 2.4 V
µA VOUT = 2.4 V
µA VOUT = VOLmax
µA VIN = VIHmin
µA VIN = VILmax
XTAL1 input current
Pin capacitance10)
(digital inputs/outputs)
IIL CC –
CIO CC –
±20
µA 0 V < VIN < VDD
10
pF f = 1 MHz
TA = 25 °C
1) Keeping signal levels within the levels specified in this table, ensures operation without overload conditions.
For signal levels outside these specifications also refer to the specification of the overload current IOV.
2) For pin RSTIN this specification is only valid in bidirectional reset mode.
3) As a rule, with decreasing output current the output levels approach the respective supply level (VOL→VSS,
VOH→VDD). However, only the levels for nominal output currents are guaranteed.
4) This specification is not valid for outputs which are switched to open drain mode. In this case the respective
output will float and the voltage results from the external circuitry.
5) These parameters describe the RSTIN pullup, which equals a resistance of ca. 50 to 250 kΩ.
6) The maximum current may be drawn while the respective signal line remains inactive.
7) The minimum current must be drawn in order to drive the respective signal line active.
8) This specification is valid during Reset and during Hold-mode or Adapt-mode. During Hold-mode Port 6 pins
are only affected, if they are used (configured) for CS output and the open drain function is not enabled. The
READY-pullup is always active, except for Powerdown mode.
9) This specification is valid during Reset and during Adapt-mode.
10) Not 100% tested, guaranteed by design and characterization.
Data Sheet
51
V1.0, 2001-10