English
Language : 

TLE6220GP_09 Datasheet, PDF (5/19 Pages) Infineon Technologies AG – Smart Quad Low-Side Switch
Data Sheet TLE 6220 GP
Electrical Characteristics cont.
Parameter and Conditions
VS = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
Symbol Values
Unit
min typ max
5. Diagnostic Functions
Open Load Detection Voltage
Output Pull Down Current
Fault Delay Time
Short to Ground Detection Voltage
Short to Ground Detection Current
VDS(OL)
IPD(OL)
td(fault)
VDS(SHG)
ISHG
6. SPI-Timing
Serial Clock Frequency (depending on SO load)
fSCK
Serial Clock Period (1/fclk)
tp(SCK)
Serial Clock High Time
tSCKH
Serial Clock Low Time
tSCKL
Enable Lead Time (falling edge of CS to rising edge of tlead
CLK)
Enable Lag Time (falling edge of CLK to rising edge of CS ) tlag
Data Setup Time (required time SI to falling of CLK)
tSU
Data Hold Time (falling edge of CLK to SI)
tH
Disable Time @ CL = 50 pF8
tDIS
Transfer Delay Time7
tdt
( CS high time between two accesses)
Data Valid Time
CL = 50 pF tvalid
CL = 100 pF8
CL = 220 pF8
VS -2.5 VS -2 VS -1.3 V
50 90
150
µA
50 110 200
µs
VS –3.3 VS -2.9 VS -2.5 V
-50 -100 -150 µA
DC --
200 --
50 --
50 --
250 --
250 ---
20 --
20 --
--
--
200 --
--
--
--
--
--
--
5
MHz
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
150 ns
--
ns
110 ns
120
150
7 This time is necessary between two write accesses. To get the correct diagnostic information, the transfer delay
time has to be extended to the maximum fault delay time td(fault)max = 200µs.
8 This parameter will not be tested but guaranteed by design
V2.2
Page 5
2009-11-18