English
Language : 

TLE4946-1L Datasheet, PDF (5/9 Pages) Infineon Technologies AG – High Precision Hall-Effect Switch
TLE4946-1L
AC/DC Characteristics
over operating range, unless otherwise specified. Typical values correspond to VS=12V
and TA=25°C.
Parameter
Symbol min. typ. max. Unit Conditions
Supply Current
Reverse Current
Output Saturation Voltage
Output Leakage Current
Output Fall Time
Output Rise Time
Chopper Frequency
Switching Frequency
Delay Time2)
Output Jitter3)
IS
ISR
VQSAT
IQLEAK
tf
tr
fOSC
fSW
td
tQJ
2
4
6
mA VS = 2.7V .. 18V
0
0.2
1
mA VS= -18V
-
0.3 0.6
V IQ= 20mA
- 0.05 10 µA for VQ=18 V
- 0.02 1
µs RL= 1.2 kOhm ;CL=50pF
-
0.4
1
µs RL= 1.2 kOhm ;CL=50pF
- 320 - kHz
0
-
151) kHz
-
13
-
µs
-
1
- µsRMS B = Square-Wave Signal
1kHz
Repeatability of magnetic
thresholds4)
BREP
-
20
- µTRMS ∆B/∆t>12mT/ms
Power-On Time5)
Thermal Resistance6)
tPON
RthJA
-
13
-
µs VS >= 2.7V
-
- 190 K/W
P-SSO-3-2
1) To operate the sensor at the max. switching frequency, the value of the magnetic signal
amplitude must be 1.4 times higher than for static fields. This is due to the -3dB corner frequency
of the low pass filter in the signal path.
2) Systematic delay between magnetic threshold reached and output switching.
3) Jitter is the unpredictable deviation of the output switching delay.
4) BREP is equivalent to the noise constant.
5) Time from applying VS >= 2.7 V to the sensor until the output state is valid.
6) Thermal resistance from junction to ambient.
e.g.: VS=12.0 V, IS_typ=4 mA, VQSAT_typ=0.3 V, IQ=20 mA => Power Dissipation Pdis=54.0 mW.
In TA = Tj – (RthJA * Pdis) = 175 °C – (190 K/W * 0.054 W) => TA = 164.7 °C
Magnetic Characteristics
over operating range, unless otherwise specified. Typical values correspond to VS=12V.
Parameter
Symbol Tj [°C] min. typ. max. Unit Conditions
Operate Point
TLE4946-1L
BOP
mT
-40 11.3 15.4 19.5
25 11.0 15.0 19.0
150 10.5 14.3 18.1
Release Point
TLE4946-1L
BRP
mT
-40 -19.5 -15.4 -11.3
25 -19.0 -15.0 -11.0
150 -18.1 -14.3 -10.5
Hysteresis
TLE4946-1L
BHYS
mT
-40
-
-
-
25 22.0 30.0 38.0
150
-
-
-
Temperature
TC
ppm/°C
Compensation of
Magnetic Thresholds
-
- -350 -
Positive magnetic fields related with south pole of magnet to the branded side of package.
Note: Typical characteristics specify mean values expected over the production spread.
Data Sheet
5/9
2004-03-04