English
Language : 

TLE4913 Datasheet, PDF (5/12 Pages) Infineon Technologies AG – Low Power Hall Switch
Operating Range
Parameter
Symbol
Limit Values
Unit
Min. typ. max.
Supply voltage
VS
2.4
2.7
5.5
V
Output voltage
VQ
– 0.3 2.7
5.5
V
Ambient Temperature TA
– 40 25
85
°C
1) A Ceramic Bypass Capacitor of 100 nF at VS to GND is highly recommended.
Notes
1)
AC/DC Characteristics
Parameter
Symbol
Averaged Supply Current ISAVG
Averaged Supply
Current
ISOPAVG
during Operating Time
Transient Peak Supply ISOPT
Current
during Operating Time
Supply Current
during Standby Time
ISSTB
Output Saturation Voltage VQSAT
Output Leakage Current IQLEAK
Output Rise Time
tr
Limit Values
Min. typ. Max.
1
4
20
0.5
1.1
2.5
–
–
2.5
1
3.5
20
–
0.13 0.4
–
0.01 1
–
0.5 1
Unit
µA
mA
mA
µA
V
µA
µs
Output Fall Time
Operating Time
Standby Time
Duty Cycle
Start-up Time of IC
tf
–
top
15
tstb
–
top / tstb –
tstu
–
0.1 1
µs
50
130
0.039
6
93 1) 2) µs
240 3) ms
–
%
12
µs
Notes
t < 100 ns
IQ = 1 mA
RL = 2.7 kΩ;
CL = 10 pF
RL = 2.7 kΩ;
CL = 10 pF
4)
1) for VS=3.5V the max. Operating Time top max = 85µs
2) includes the Start-up Time tstu
3) for VS=3.5V the max. Standby Time tstb max = 220ms
4) initial power on time. VS must be applied in this time ( typ. 6µs to max. 12µs ) to get already a valid output
state after the first operating phase (typ. 56µs). For rise times of VS > 12µs, the output state is valid after the
second operating phase (includes one standby phase), e.g. happens only when the battery in flip phones is
changed.
Data Sheet
5
V 2.2, 2004-03-09