English
Language : 

Q67006-A9315 Datasheet, PDF (5/17 Pages) Infineon Technologies AG – Smart Quad Low-Side Switch
Data Sheet TLE 6220 GP
Electrical Characteristics cont.
Parameter and Conditions
VS = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
Symbol Values
min typ
Unit
max
5. Diagnostic Functions
Open Load Detection Voltage
Output Pull Down Current
Fault Delay Time
Short to Ground Detection Voltage
Short to Ground Detection Current
VDS(OL)
IPD(OL)
td(fault)
VDS(SHG)
ISHG
6. SPI-Timing
Serial Clock Frequency (depending on SO load)
Serial Clock Period (1/fclk)
Serial Clock High Time
Serial Clock Low Time
Enable Lead Time (falling edge of CS to rising edge of
CLK)
Enable Lag Time (falling edge of CLK to rising edge of CS )
Data Setup Time (required time SI to falling of CLK)
Data Hold Time (falling edge of CLK to SI)
Disable Time @ CL = 50 pF8
Transfer Delay Time7
( CS high time between two accesses)
Data Valid Time
CL = 50 pF
CL = 100 pF8
CL = 220 pF8
fSCK
tp(SCK)
tSCKH
tSCKL
tlead
tlag
tSU
tH
tDIS
tdt
tvalid
VS -2.5 VS -2 VS -1.3
V
50 90
150
µA
50 110 200
µs
VS –3.3 VS -2.9 VS -2.5
V
-50 -100 -150 µA
DC --
200 --
50 --
50 --
250 --
250 ---
20 --
20 --
--
--
200 --
--
--
--
--
--
--
5
MHz
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
--
ns
150 ns
--
ns
110 ns
120
150
7 This time is necessary between two write accesses. To get the correct diagnostic information, the transfer delay
8
time
This
has to be extended to the maximum fault delay time td(fault)max
parameter will not be tested but guaranteed by design
=
200µs.
V1.1
Page 5