6.3
Electrical Characteristics
TLE9262QX
Voltage Regulator 1
Table 9 Electrical Characteristics
VS = 5.5 V to 28 V; Tj = -40 °C to +150 °C; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Parameter
Symbol
Values
Unit Note / Test Condition Number
Output Voltage including line VCC1,out1
and Load regulation
Min. Typ. Max.
4.9 5.0 5.1 V
Output Voltage including line
and Load regulation
Output Voltage including line
and Load regulation
VCC1,out2
VCC1,out3
4.9 5.0
4.97 –
5.1 V
5.07 V
1)SBC Normal Mode;
10µA < IVCC1 < 250mA
6V < VS < 28V
1)SBC Normal Mode;
10µA < IVCC1 < 150mA
1)2)SBC Normal Mode;
20mA < IVCC1 < 90mA
8V < VS < 18V
25°C < Tj < 125°C
P_6.3.1
P_6.3.7
P_6.3.12
Output Voltage including line VCC1,out41 4.9 5.05 5.2 V
and Load regulation
SBC Stop Mode;
P_6.3.2
1mA < IVCC1 < IVCC1,Ipeak
Output Voltage including line VCC1,out42 4.9
and Load regulation
5.05 5.25 V
SBC Stop Mode;
10µA < IVCC1 < 1mA
P_6.3.20
Output Drop
VCC1,d1
–
–
500 mV IVCC1 = 50mA
VS=3V
P_6.3.3
Output Drop
VCC1,d2
–
VCC1 Active Peak Threshold 1 IVCC1,Ipeak1,r –
(Transition threshold between
low-power and high-power
mode regulator)
–
500 mV IVCC1 = 150mA
VS=5V
1.9 3.5
mA 2) ICC1 rising;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘0’
P_6.3.4
P_6.3.13
VCC1 Active Peak Threshold 1 IVCC1,Ipeak1,f 0.5 1.3 –
(Transition threshold between
high-power and low-power
mode regulator)
mA 2) ICC1 falling;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘0’
P_6.3.17
VCC1 Active Peak Threshold 2 IVCC1,Ipeak2,r –
(Transition threshold between
low-power and high-power
mode regulator)
4.3 7.0
mA 2) ICC1 rising;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘1’
P_6.3.18
VCC1 Active Peak Threshold 2 IVCC1,Ipeak2,f 1.7 3.4 –
(Transition threshold between
high-power and low-power
mode regulator)
mA 2) ICC1 falling;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘1’
P_6.3.19
Over Current Limitation
IVCC1,lim
250 –
12002) mA
current flowing out of
pin, VCC1 = 0V
P_6.3.6
1) In SBC Stop Mode, the specified output voltage tolerance applies when IVCC1 has exceeded the selected active peak
I I threshold ( VCC1,Ipeak1,r or VCC1,Ipeak2,r) but with increased current consumption.
2) Not subject to production test, specified by design.
Data Sheet