English
Language : 

TLE6220GP_07 Datasheet, PDF (4/19 Pages) Infineon Technologies AG – Smart Quad Low-Side Switch Short Circuit Protection
Data Sheet TLE 6220 GP
Electrical Characteristics
Parameter and Conditions
VS = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
Symbol Values
min typ
1. Power Supply, Reset
Supply Voltage4
Supply Current 5
Minimum Reset Duration
(After a reset all parallel inputs are ORed with the SPI data
bits)
VS
IS
tReset,min
4.5 --
--
1
10
2. Power Outputs
ON Resistance VS = 5 V; ID = 1 A
TJ = 25°C
RDS(ON)
--
TJ = 150°C
--
0.32
--
Output Clamping Voltage
output OFF
VDS(AZ)
45 53
Current Limit
Output Leakage Current
VRESET = L
ID(lim)
ID(lkg)
3
4.5
--
--
Turn-On Time
ID = 1 A, resistive load tON
--
5
Turn-Off Time
ID = 1 A, resistive load tOFF
--
5
3. Digital Inputs
Input Low Voltage
Input High Voltage
VINL
VINH
- 0.3 --
2.0 --
Input Voltage Hysteresis
Input Pull Down/Up Current (IN1 ... IN4)
PRG, RESET Pull Up Current
Input Pull Down Current (SI, SCLK)
Input Pull Up Current (CS )
4. Digital Outputs (SO, FAULT )
SO High State Output Voltage
ISOH = 2 mA
SO Low State Output Voltage
Output Tri-state Leakage Current
FAULTOutput Low Voltage
ISOL = 2.5 mA
CS = H, 0 ≤ VSO ≤ VS
IFAULT = 1.6 mA
Current Limitation; Overload Threshold Current
Overtemperature Shutdown Threshold
Hysteresis6
VINHys
50
IIN(1..4)
20
IIN(PRG,Res) 20
IIN(SI,SCLK)
10
IIN(CS)
10
100
50
50
20
20
VSOH
VSOL
ISOlkg
VFAULTL
ID(lim) 1...4
Tth(sd)
Thys
VS - 0.4 --
--
--
-10 0
--
--
3
4.5
170 --
--
10
Unit
max
5.5
V
2
mA
µs
0.4
Ω
0.7
60
V
6
A
10
µA
10
µs
10
µs
1.0
V
VS+0.
V
3
200 mV
100
µA
100
µA
50
µA
50
µA
--
V
0.4 V
10
µA
0.4
V
6
A
200
°C
--
K
4 For VS < 4.5V the power stages are switched according the input signals and data bits or are definitely
switched off. This undervoltage reset gets active at VS = 3V (typ. value) and is guaranteed by design.
5 If Reset = L the supply current is reduced to typ. 20µA
6 This parameter will not be tested but guaranteed by design
V2.1
Page 4
2007-05-03