7.4
Electrical Characteristics Diagnostic Function
BTS5090-2EKA
Diagnostic Functions
Table 9 Electrical Characteristics: Diagnostics
VS = 8 V to 18 V, TJ = -40°C to +150°C (unless otherwise specified).
Typical values are given at VS = 13.5 V, TJ = 25 °C
Parameter
Symbol
Values
Min. Typ. Max.
Unit Note /
Test Condition
Number
Load Condition Threshold for Diagnostic
Open load detection
threshold in OFF state
VS - VOL(OFF) 4
–
6
V
1) VIN = 0 V
VDEN = 4.5 V
See Figure 26
P_7.5.1
Open load detection
threshold in ON state
IL(OL)
5
–
30
mA VIN = VDEN = 4.5 V
P_7.5.2
IIS(OL) = 8 μA
See Figure 24
See Figure 46
Sense Pin
IS pin leakage current when IIS_(DIS)
–
–
1
μA 1) VIN = 4.5 V
P_7.5.4
sense is disabled
VDEN = 0 V
IL = IL4 = 4 A
Sense signal saturation
VS - VIS
0
–
3
V
3) VIN = 0 V
P_7.5.6
voltage
(RANGE)
VOUT = VS > 10 V
VDEN = 4.5 V
IIS = 6 mA
See Figure 47
Sense signal maximum
current in fault condition
IIS(FAULT)
6
15
35
mA VIS = VIN = VDSEL = 0 V P_7.5.7
VOUT = VS > 10 V
VDEN = 4.5 V
See Figure 20
See Figure 48
Sense pin maximum voltage VIS(AZ)
41
47
53
V IIS = 5 mA
See Figure 20
P_7.5.3
Current Sense Ratio Signal in the Nominal Area, Stable Load Current Condition
Current sense ratio
IL0 = 50 mA
Current sense ratio
IL1 = 0.5 A
Current sense ratio
IL2 = 1 A
Current sense ratio
IL3 = 2 A
Current sense ratio
IL4 = 4 A
kILIS derating with current and
temperature
kILIS0
kILIS1
kILIS2
kILIS3
kILIS4
ΔkILIS
-50
1650 +50 % VIN = 4.5 V
P_7.5.8
VDEN = 4.5 V
-16
1500 +16 % See Figure 21
P_7.5.9
TJ = -40 °C; 150 °C
-10 1480 +10 %
P_7.5.10
-7
1480 +7
%
P_7.5.11
-6.5 1480 +6.5 %
P_7.5.12
-5
0
+5
%
3) kILIS3 versus kILIS2
P_7.5.17
See Figure 22
Diagnostic Timing in Normal Condition
Data Sheet
PROFET™+ 12V
34