English
Language : 

ICB1FL02G_08 Datasheet, PDF (33/37 Pages) Infineon Technologies AG – Smart Ballast Control IC for Fluorescent Lamp Ballasts
ICB1FL02G
Application Examples
Detection of capacitive mode operation via C18:
The DC level at pin RES is set by R36 and the source current IRES3. The preferred AC level is in the range between
∆VACRES= 1,5V to 2,0V at a ∆VBUS= 410V.
Selected value: C18= 82pF.
C18
=
C19 ⋅ ∆-----V∆----VA----B-C----U-R----SE----S--
=
22nF ⋅ ---2----V------
410 V
=
107 p F
Bandpass filters L21/C21 and L22/C22 can be used in order to conduct filament currents preferred at preheating
frequency and to suppress these currents during run mode.
Inductor L1 of the boost converter:
The inductivity of the boost inductor typically is designed to operate within a specified voltage range above a
minimum frequency in order to get an easier RFI suppression. It is well known, that in critical conduction mode
(CritCM) there is a minimum operating frequency at low input voltages and another minimum at maximum input
voltage. In state-of-the-art CritCM PFC controllers we use the lowest value out of these two criterias:
At minimum AC input voltage:
2
LA = (---V----I---N-----A-----C----M------I--N-4-----⋅⋅---F---M-2----)-I---N--⋅----⋅(--V-P---OB-----UU-----TS----P-–---F-(--CV-----I-⋅--N-V---A--B---C-U----M-S-----I--N------⋅-------2---)---)---⋅---η--
2
LA
=
(---1---8---0---V------⋅-------2----)------⋅---(---4---1---0---V------–-----(--1---8---0----V-----⋅--------2---)---)---⋅---0---,---9---5--
4 ⋅ 25kHz ⋅ 60 W ⋅ 410V
=
3, 89mH
At maximum AC input voltage
2
LB = (---V----I---N-----A-----C----M------A-----X-4----⋅⋅---F----M-2---)--I--N---⋅---(⋅--V-P---O-B----UU-----TS----P-–---F-(---CV-----I⋅--N-V----A-B---C-U----M-S-----A-----X------⋅-------2---)--)----⋅---η--
2
LB
=
(---2---7---0---V------⋅--------2---)-------⋅---(--4---1---0---V------–-----(--2---7---0----V------⋅-------2---)---)---⋅---0---,---9---5--
4 ⋅ 25kHz ⋅ 60 W ⋅ 410V
=
1, 58mH
With the new control principle for the PFC preconverter we have a third criteria that covers the maximum on-time
tPFCOM-MAX= 23,5µs:
2
LC = (---V----I---N-----A-----C----M------4I--N--⋅---P-⋅---O----2-U---)-T-----P-⋅--F-T---C-O----N-----M------A-----X-----⋅----η--
2
LC = (---1---8---0----⋅--------2---)-------⋅---2---3---,---5---µ----s----⋅---0---,---9---5-- = 6, 03mH
4 ⋅ 60 W
With the assumed conditions the lowest value out of LA, LB, LC is 1,58mH.
Selected value: L1= 1,58mH.
Datasheet Version 2.1
33
September 2008