English
Language : 

BTT6010-1EKB_15 Datasheet, PDF (31/48 Pages) Infineon Technologies AG – Smart High-Side Power Switch Single Channel
BTT6010-1EKB
IIS(FAULT)
IS
OL
comp.
GND
ZGND
RIS
Diagnostic Functions
Vbat
VS
SOL
ROL
OUT
ILOFF
Ileakage
VOL(OFF)
RPD
Rleakage
Open Load in OFF.svg
Figure 25 Open Load Detection in OFF Electrical Equivalent Circuit
7.3.3.3 Open Load Diagnostic Timing
Figure 26 shows the timing during either Open load in ON or OFF condition when the DEN pin is HIGH. Please
note that a delay tsIS(FAULT_OL_OFF) has to be respected after the falling edge of the input and rising edge of the DEN,
when applying an open load in OFF diagnosis request, otherwise the voltage VOUT cannot be guaranteed and the
diagnosis can be wrong.
Load is present
VIN
Open load
VOUT
RDSON x IL
IOUT
t
VOL(OFF)
t
VDEN
IIS
90% of IIIS(FAULT) static
tsIS(LC)
Figure 26 SENSE Signal in Open Load Timing
Data Sheet
31
PROFET™+ 24V
t
tsIS(FAULT_OL_OFF)
t
Error Settling Disabling Time.vsd
Rev. 1.0, 2015-10-01