BTS5120-2EKA
Protection Functions
6.6
Electrical Characteristics for the Protection Functions
Table 6 Electrical Characteristics: Protection
VS = 8 V to 18 V, TJ = -40°C to +150°C (unless otherwise specified).
Typical values are given at VS = 13.5 V, TJ = 25 °C
Parameter
Symbol
Values
Unit
Min. Typ. Max.
Loss of Ground
Output leakage current while IOUT(GND) –
0.1 –
mA
GND disconnected
Reverse Polarity
Drain source diode voltage VDS(REV)
during reverse polarity
200 650 700 mV
Overvoltage
Overvoltage protection
Overload Condition
Load current limitation
VS(AZ)
IL5(SC)
41
47
53
V
9
12
15
A
Load current limitation
IL28(SC)
–
6
–
A
Short circuit current during IL(RMS)
–
2
–
A
over temperature toggling
Dynamic temperature
ΔTJ(SW)
–
increase while switching
Thermal shutdown
temperature
TJ(SC)
150
Thermal shutdown hysteresis ΔTJ(SC)
–
1) All pins are disconnected except VS and OUT.
2) Not Subject to production test, specified by design
3) Test at TJ = -40°C only
4) Functional test only
5) Test at TJ = +150°C only
80
–
K
170 4) 200 4) °C
20
–
K
Note /
Test Condition
Number
1) 2) VS = 28 V
See Figure 14
P_6.6.1
IL = - 1 A
TJ = 150 °C
See Figure 17
P_6.6.2
ISOV = 5 mA
See Figure 16
P_6.6.3
3)VDS = 5 V
See Figure 18 and
Figure 43
2) VDS = 28 V
See Figure 18 and
Figure 44
2) VIN = 4.5 V
RSHORT = 100 mΩ
LSHORT = 5 μH
4) See Figure 19
P_6.6.4
P_6.6.7
P_6.6.12
P_6.6.8
5) See Figure 19 P_6.6.10
5) 4) See Figure 19 P_6.6.11