English
Language : 

TLE6209R Datasheet, PDF (25/28 Pages) Infineon Technologies AG – 7 A H-Bridge for DC-Motor Applications
TLE 6209 R
CSN High to Low & SCLK stays Low: Status information of Data Bit 0 ( Error Flag )
is transfered to SDO
CSN
time
SCLK
SDI
SDO tristate
SDI: Data is not accepted
0_
tristate
SDO: Status information of Data Bit 0 ( Error-Flag ) will stay as long as CSN is low
Figure 8 Timing for Error Detection Only
CSN
SCLK
SDI
tSCLKH
tlead
tbef
tSDISU
tSCLKL
tSDIHO
Don´t care
Valid
Don´t
care
0.7 VCC
0.2 VCC
tlag
tbeh
0.7 VCC
0.2 VCC
Valid
0.7 VCC
Don´t care
0.2 VCC
Figure 9 SPI-Input Timing
Data Sheet, Version 3.0
25
2001-10-15