TDA5251 F1
Version 1.1
Functional Description
The I2C / 3-wire Bus Interface gives an external microcontroller full control over important system
parameters at any time.
It is possible to set the device in three different modes: Slave Mode, Self Polling Mode and Timer
Mode. This is done by a state machine which is implemented in the WAKEUP LOGIC unit. A
detailed description is given in Section 2.4.16.
The DATA VALID DETECTOR contains a frequency window counter and an RSSI threshold
comparator. The window counter uses the incoming data signal from the data slicer as the gating
signal and the crystal oscillator frequency as the timebase to determine the actual datarate. The
result is compared with the expected datarate.
The threshold comparator compares the actual RSSI level with the expected RSSI level.
If both conditions are true the PwdDD pin is set to LOW in self polling mode as you can see in
Section 2.4.16. This signal can be used as an interrupt for an external µP. Because the PwdDD
pin is bidirectional and open drain driven by an internal pull-up resistor it is possible to apply an
external LOW thus enabling the device.
2.4.15 Bus Interface and Register Definition
The TDA5251 supports the I2C bus protocol (2 wire) and a 3-wire bus protocol. Operation is
selectable by the BusMode pin (pin 2) as shown in the following table. All bus pins (BusData,
BusCLK, EN, BusMode) have a Schmitt-triggered input stage. The BusData pin is bidirectional
where the output is open drain driven by an internal 15kΩ pull up resistor.
Table 2-6 Bus Interface Format
Function
I2C Mode
BusMode
Low
3-wire Mode
High
EN
High= inactive,
Low= active
BusCLK
Clock input
BusData
Data in/out
BusData
16
BusCLK
17
EN
24
BusMode
2
I2C / 3-wire INTERNAL BUS
INTERFACE
11100000
CHIP ADDRESS
Figure 2-7 Bus Interface
i2c_3w_bus.wmf
Note: The Interface is able to access the internal registers at any time, even in POWER DOWN
mode. There is no internal clock necessary for Interface operation.