English
Language : 

PMB2341 Datasheet, PDF (23/26 Pages) Infineon Technologies AG – 10-pin Single PLL
Confidential
PMB 2341
preliminary
Reference
5.3 Typical Power-On Time
Time required to turn PLL and/or LO-buffer-chain frominstalled standby-mode
to mode ALLRUN. Time is measured from time point when the ENable-signal is
sent on 3-wire bus after programming the apropriate data bits.
Table 5-3
Previously installed standby mode
(see Table 5)
AMPRUN
ALLOFF
Turn-ON-
time
t.b.d
1
Units
µs
µs
Remarks
see Note
1)
NOTE 1: Only the turn-on time from PLL is measured, not the required lock-in time, which strongly depends on
the loopfilter, etc.
5.4 Typical Supply current
Table 5-4
Standby mode
(see Table 5)
ALLRUN
ALLOFF
CMOS-
Supply
IDD
1.4
0
Bipolar
Supply
ICC
5.5
0
Units
Test item
Test
condition
mA
1.1
mA
1.2
see Note
1)
Note 1) : Room temperature, All supplies set to 3.2V, TA = 27 °C, fRI = 13MHz, fLO = 1.2GHz, internal fref =
200KHz, PLL locked in mode ALLRUN, charge pump output current set to 4mA. No bus programming activities.
Values may vary within 10%.
Wireless Components
5-3
Specification, February 2000