Block Description and Electrical Characteristics
Electrical Characteristics Reset Function
VI = 13.5 V, -40 °C ≤ Tj ≤ 150 °C, all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Pos. Parameter
Symbol
Limit Values
Unit Conditions
Min. Typ. Max.
Output Undervoltage Reset
5.3.1
Default Output Undervoltage Reset VRT
Switching Thresholds
4.5
4.65 4.8
V
VQ decreasing
Output Undervoltage Reset Threshold Adjustment
5.3.2 Reset Adjust
Switching Threshold
VRADJ,th 1.26 1.35 1.44 V
3.5 V ≤ VQ < 5 V
5.3.3 Reset Adjustment Range1)
Reset Output RO
VRT,range 3.50
–
4.65 V
–
5.3.4 Reset Output Low Voltage
5.3.5 Reset Output Internal Pull-Up
Resistor to VQ
5.3.6 Optional Reset Output External
Pull-up Resistor to VQ
Reset Delay Timing
VRO,low
–
RRO
10
RRO,ext
20
0.1
0.4
V
1 V ≤ VQ ≤ VRT
no external RRO,ext
20
40
kΩ –
–
–
kΩ
1 V ≤ VQ ≤ VRT ;
VRO ≤ 0.4 V
5.3.7
5.3.8
5.3.9
Delay Pin Output Voltage
Power On Reset Delay Time
Upper Delay
Switching Threshold
VD
–
–
5
V
–
trd
17
28
39
ms CD = 100 nF
VDU
–
1.8
–
V
–
5.3.10 Lower Delay
Switching Threshold
VDL
–
0.45 –
V
–
5.3.11 Delay Capacitor
Charge Current
ID,ch
–
6.5
–
µA VD = 1 V
5.3.12 Delay Capacitor
Reset Discharge Current
ID,dch
–
70
–
mA VD = 1 V
5.3.13 Delay Capacitor
Discharge Time
trr,d
–
1.9
3
5.3.14 Internal Reset Reaction Time
5.3.15 Reset Reaction Time
trr,int
–
trr,total
–
3
7
4.9
10
1) VRT is scaled linearly, in case the Reset Switching Threshold is modified
2) parameter not subject to production test; specified by design
µs Calculated Value:
trr,d = CD*(VDU -
VDL)/ ID,dch
CD = 100 nF
µs
CD = 0 nF 2)
µs Calculated Value:
trr,total = trr,int + trr,d
CD = 100 nF
Data Sheet
21
Rev. 1.1, 2008-10-07