TLD2314EL
Load Diagnosis
8.3
Double Fault Conditions
The TLD2314EL allows the diagnosis of each channel separately, as long as the ST-pin is shorted to GND The
diagnosis filter times tOL and tSC (Pos. 8.4.9 and Pos. 8.4.12) are valid only for the channel, which diagnoses first
the fault condition. For the other channel or channels with a subsequential fault the diagnosis is reported
immediately without the diagnosis filter time, if the filter time tOL has been elapsed for the channel with the first
fault. During activation via IN_SET of a non-faulty output, where one channel has already a fault detected, a short
spike to VIN_SET(OL/SC) could occur on the channel, which should be activated. Therefore, in general a diagnosis
should be done earliest after the diagnosis filter times tOL and tSC to avoid any incorrect diagnosis readout. In the
scenario mentioned above the turn on time tON(IN_SET) could be extended. The following figure shows the example
behavior, if OUT1 has a fault and OUT2 is operated in PWM-mode. OUT3 is disabled.