3.4
Characteristics
KP235
Analog Absolute Pressure Sensor
Specification
Table 8 Electrical Characteristics
Parameter
Symbol
Values
Unit Note / Test Condition Number
Min.
Typ.
Max.
Output voltage
VOUT_R
0.10
–
range
4.85
V
See also section
3.1
“Output Voltage
versus Load” on
Page 15
Supply current
IDD
–
Output referred
noise
VNOISE
–
–
Response time2) tR
–
8
–
–
0.65
10
2.5
1.8
1.03)
mA During power up a peak 3.2
supply current of max.
22 mA is possible
mVRMS Frequency > 1 kHz1) 3.3
mVRMS Frequency < 1 kHz
ms 10% to 90% of the final 3.4
output value
Stabilization time2) tS
–
–
10
ms For full accuracy
3.5
Power-up time2)
tUP
–
–
5
ms 90% of the final output 3.6
value
Broken wire:
tOBD
–
–
1
ms
3.7
Diagnosis response
time4)
OBD transistor on RDSON
–
–
160
Ω
3.8
resistance
1) 200 measurements in sequence, bandwidth limited to 40kHz
2) More details in section “Timing Properties” on Page 16
3) The maximum response time considers a maximal value of 100nF for the output blocking capacitor C2 and a maximum
pressure pulse equivalent 4.0V output change
4) In the event of a broken wire (broken VDD line or broken GND line), the output changes to certain voltage levels within the
broken wire response time. The OBD ranges are determined by the application circuitry
Data Sheet
20
Revision 1.0, 2010-06-21