Smart High-Side Power Switch
BTS 5234L
In case of over current as well as over temperature, the current sense signal is switched
off. As a result, one threshold is enough to distinguish between normal and faulty
operation. Open load and over load can be differentiated by switching off the channel
and using open load detection in off-state.
Details about timings between the diagnosis signal IIS and the output voltage VOUT and
load current IL in ON-state can be found in Figure 15.
IN
OFF ON
VOUT
tON
t
t
IL
IIS
tsIS(ON)
tsIS(LC)
t
Figure 15 Timing of Diagnosis Signal in ON-state
t
SwitchOn .emf
4.3.2 OFF-State Diagnosis
Details about timings between the diagnosis signal IIS and the output voltage VOUT and
load current IL in OFF-state can be found in Figure 16.
IN
ON
OFF
VOUT
tOFF
t
Open Load
t
IL
IIS
td(fault)
ts(fault)
Figure 16 Timing of Diagnosis Signal in OFF-state
VIS(fault) / RS
t
t
SwitchOff.emf