Circuit Description
The TLE 4299 is a PNP based very low drop linear voltage regulator. It regulates the
output voltage to VQ = 3.3 V for an input voltage range of 4.4 V ≤ VI ≤ 45 V. The control
circuit protects the device against potential damages caused by overcurrent and
overtemperature.
The internal control circuit achieves a 3.3 V output voltage with a tolerance of ± 2%.
The device includes a power on reset and an under voltage reset function with adjustable
reset delay time and adjustable reset switching threshold as well as a sense control/early
warning function. The device includes an inhibit function to disable it when the ECU is
not used for example while the motor is off.
The reset logic compares the output voltage VQ to an internal threshold. If the output
voltage drops below this level, the external reset delay capacitor CD is discharged. When
VD is lower than VST, the reset output RO is switched Low. If the output voltage drop is
very short, the VST level is not reached and no reset-signal is asserted. This feature
avoids resets at short negative spikes at the output voltage e.g. caused by load changes.
As soon as the output voltage is more positive than the reset threshold, the delay
capacitor is charged with constant current. When the voltage reaches VDT the reset
output RO is set High again.
The reset delay time and the reset reaction time are defined by the external capacitor
CD. The reset function is active down to VI = 1 V.
In addition to the normal reset function, the device gives an early warning. When the SI
voltage drops below VSI,low, the devices asserts the SI output Low to indicate the logic
and the µ-processor that this voltage has dropped. The sense function uses a hysteresis:
When the SI-voltage reaches the VSI,high level, SO is set high again. This feature can be
used as early warning function to notice the µ-controller about a battery voltage drop and
a possible reset in a short time. Of course also any other voltage can be observed by this
feature.
The user defines the threshold by the resistor-values RSI1 and RSI2.
For the exact timing and calculation of the reset and sense timing and thresholds, please
refer to the application section.
Datasheet
2
Rev. 1.1, 2007-10-17